![Faulhaber MC 5004 P STO Installation Instructions Manual Download Page 33](http://html.mh-extra.com/html/faulhaber/mc-5004-p-sto/mc-5004-p-sto_installation-instructions-manual_546613033.webp)
1st edition, 03-05-2018
7000.05063, 1st edition, 03-05-2018
7000.05063
Installation
33
24
Index
Index channel (logically inverted signal)
25
n.c.
–
26
n.c.
–
27
DigOut 1
Digital output
28
DigOut 2
Digital output
29
n.c.
–
30
U
DD
Power supply for sensors
31
GND
Ground connection
32
DigIn 1
Digital input
33
DigIn 2
Digital input
34
DigIn 3
Digital input
35
DigIn 4
Digital input
36
STO GND 2
Ground connection for STO input 2
37
STO IN 2
Signal STO 2
38
STO IN 1
Signal STO 1
39
STO GND 1
Ground connection for STO input 1
40
AGND
Analogue ground connection
41
AnIn 1
Analogue input
42
AnIn 2
Analogue input
43
STO Out 1 Status
STO status message (active/inactive)
44
STO 24V In
Supply of the status outputs
45
STO Out 2 No-Error
STO error message (ok/nok)
46
CAN-H
CAN-High interface
47
CAN-L
CAN-Low interface
48
GND
Ground connection
49
TxD
RS232 interface transmit direction
50
RxD
RS232 interface receive direction
Pin
Designation
Meaning
Summary of Contents for MC 5004 P STO
Page 1: ...WE CREATE MOTION Installation Instructions MC 5004 P STO Original Instructions EN ...
Page 64: ...1st edition 03 05 2018 7000 05063 1st edition 03 05 20187000 05063 Additional documents 64 ...
Page 65: ...1st edition 03 05 2018 7000 05063 1st edition 03 05 20187000 05063 Additional documents 65 ...
Page 67: ...1st edition 03 05 2018 7000 05063 1st edition 03 05 20187000 05063 Additional documents 67 ...
Page 68: ...1st edition 03 05 2018 7000 05063 1st edition 03 05 20187000 05063 Additional documents 68 ...