Adjustment Work on the Bondhead
© 2020 F&S BONDTEC Semiconductor GmbH. All rights reserved.
54
11.3.5 Bracket Settings Heavy Ribbon Kit
Figure 11.3. - 1
Bracket settings HR-Kit
1. Opening width wire clamp.
>>
Open locknut
>>
Adjust stop
2. Adjust the force of the wire clamp.
3. Distance to the tool.
>>
Loosen the fastening screws of the HR kit
>>
Move the entire kit
4. Adjust the height of the wire guide.
>>
Loosen brass clamping screw
>>
Move guide by hand
>>
The adjustable stop screw allows precise adjustment
IMPORTANT!
The clamping pressure must only be adjusted to the wire diameter if necessary!
Less pressure to avoid marks on thin wires.
Higher pressure to prevent the wire from slipping through when the wire is thick.
11.4 Cleaning of the Components
DANGER!
Never use sandpaper or abrasive cleaning agents to clean components. A lint-free cloth soaked in pure al-
cohol or acetone is best for cleaning all components.
11.4.1 Machine
Clean the machine and check for possible damages. Use a lint-free cloth soaked in alcohol or acetone.
After cleaning the moving parts, they may have to be lubricated again.
3
1
2
4
2