Feed in wire and bond.
The <Feed In Position> is approached with the button
In this position those functions are available, which facilitate the threading of the bonding wire.
TIP
Helpful for threading the wire is the activation of the ultrasound via the keypad. This is possible by pressing
the <Enter> key on the keypad.
With the <Bond Off> function,
the wire can be bent at a predetermined position to create a tail of the correct length (for example, after feeding in).
Flame Off.
This function is only available for the bond head type 5X10.
During the bonding process the flame is automatically removed to create a ball at the end of the wire. With the button
<Flame off / Wire Feed> you can start the FlameOff process manually.
The programmable FlameOff parameters can be found under <Page> <Global Program Settings> <Process>.
Depending on the wire diameter you can roughly select the power output in the <High> and <Low> range.
In addition, the fine adjustment of the ignition voltage by means of <Current> and <Time> in % is possible there.
With <Current> the ignition voltage is adjusted to the wire diameter, with <Time> the time how long the spark is held
is adjusted and thus the size of the melted ball is influenced.
6.3
Frequently Returning Operation
Many subwindows have a toolbar, which often contains the following icons:
Go back one object (also possible with <Page Backward>)
Move one object (also possible with <Page Forward>)
Insert an object
Delete an object