Introduction
The following instructions apply to the installation of the electric
fan. The sump temperature switch is provided as a standard
feature.
The sump temperature switch features dual settings for two
independent single-pole, double-throw circuits. Only one
circuit is used to control the fan. The remaining circuit may be
used to control a warning light, an alarm, or a motor shutdown
switch if the temperature setting is exceeded. The sump
temperature switch wiring diagram is given in Figure 1.
Refer to Figure 2 for electric fan, temperature switch and bulb
well standard mounting locations. The bulb well houses the
sump temperature probe. These mounting locations are based
on drive mounting position.
Assembly Instructions
WARNING:
Consult applicable local and national safety
codes for proper guarding of rotating members.
Lock out power source and remove all external loads from
drive before servicing drive or accessories.
1. Drain oil from the drive.
2.
ELECTRIC FAN PANEL REWORK —
The holes in the
electric fan panel must be enlarged to accommodate the
fasteners used to mount the electric fan to the shroud. Align
the fan panel to the shroud. Locate and drill four 0.4375”
(12 mm) diameter clearance holes in line with the pre-drilled
holes in the shroud.
3. Insert four 1.25” (32 mm) cap screws through the fan
mounting holes in the shroud with the threaded portion of
the cap screw away from the drive. Secure the cap screws to
the shroud with flat washer (2 washers for 4407) and nut,
see Figure 3.
4. Secure the sump temperature switch to the switch mounting
bracket. Attach the switch and mounting bracket to the fan
shroud, refer to Figure 2 for location.
5. Install the temperature probe bulb well in the designated
drain hole as shown in Figure 4. Refer to Figure 2 for bulb
well location.
CAUTION:
Sump temperature probe must be located below
oil level.
The Falk Corporation, P.O. Box 492, Zip 53201-0492
378-102
3001 W. Canal St., Zip 53208-4200, Milwaukee, WI USA Telephone : 414-342-3131
August 2004
Fax: 414-937-4359 e-mail: [email protected] web: www.falkcorp.com
Supersedes 6-92
®
a good name in industry
Quadrive Shaft Mounted Drives
•
Appendix N
Sizes 4407/M4407-4608/M4608
(Page 51 of 52)
Electric Fan Installation
L
1
L
2
CONTROL VOLTAGE
LOW CIRCUIT
MS
START FAN
MOTOR
RED
BLUE
PURPLE
SET @ 140°F
HIGH CIRCUIT
HIGH TEMP.
YELLOW
ORANGE
BROWN
SET @ 210°F
Figure 1
ELECTRIC FAN, TEMP. SWITCH & BULB-WELL STANDARD LOCATIONS
(BASED ON DRIVE MOUNTING POSITION)
DRIVE WITH MOTOR MOUNT
DRIVE W/O MOTOR MOUNT
A3
B6
C9
D12
C3
D3
3 O’CLOCK
D6
A6
6 O’CLOCK
A9
B9
9 O’CLOCK
B12
C12
12 O’CLOCK
Figure 2
CAP SCREW
SHROUD
FAN PANEL
LOCKNUT
NUT
FLAT WASHER
Figure 3
NIPPLE-PIPE
REDUCER COUPLING
BULB-WELL SPLIT NUT
(BULB-WELL LOCATION VARIES)
CAP SCREW .25 x .75
LOCK WASHER
FLAT WASHER
NUT
BRACKET
TEMPERATURE
SWITCH
LOCATION VARIES BASED ON
DRIVE CLOCK POSITION. SUMP
TEMPERATURE PROBE MUST BE
LOCATED BELOW OIL LEVEL.
CABLE STRAP
TAKE UP SLACK
CAPILLARY IN LOOP
Figure 4