Vertical Standpipe Installatio
n
Introduction
The following instructions apply to the installation of standpipe
kits to standard drives mounted for vertical operation (high
speed shaft up or down). Drawings are representative of this
series of drives and may not agree in exact detail with all drive
sizes.
NOTE: Vertical shaft drives, when filled to the proper oil level,
are completely full of oil.
High Speed Shaft Down — Figure 1.
1. After installing the drive per the Owners Manual
installation instructions, determine which of the upper
side plug locations on the drive will provide the best
location for the standpipe, observing clearance
required to remove dipstick (Dimension D, Table 1).
Discard the air vent. When the air vent location is not
used for the standpipe, relocate the pipe plug from the
selected standpipe location to the air vent location.
Recoat pipe plug threads with Permatex #3 or
equivalent sealant before reinstalling.
2. Coat all pipe threads of kitted parts with Permatex #3 or
equivalent sealant.
3. Assemble kitted parts to the drive as illustrated in Figure 1
and then secure the standpipe with an external support to
maintain its vertical position.
4. Carefully measure Dimension X as illustrated in Figure 1.
5. From Table 1:
X + A equals oil level “Full” mark.
X + B equals oil level “Low” mark.
X + C equals dipstick length.
6. Scribe Dimensions X + A and X + B on the dipstick as
illustrated in Figure 1. Make measurements from the felt pad
in the dipstick cap.
7. Lightly chisel permanent oil level marks on the scribed lines
and cut the dipstick to the length marked. File end of
dipstick smooth.
8. Install magnetic drain plug (furnished) in oil drain location.
9. Remove the oil filler plug. Add oil until the oil level reaches
the “Full” mark on the dipstick. Coat the filler plug (not
vented) with Permatex #3 or equivalent sealant and replace
it.
10. Filler plug must always be removed to relieve entrapped air
before checking oil level.
High Speed Shaft Up — Figure 2.
1. After installing the drive per the Owners Manual installation
instructions, determine which of the lower four side plug
locations on the drive will provide the best location for the
standpipe, observing clearance required to remove dipstick
(Dimension D, Table 1). Discard the air vent. When the air
vent location is not used for the standpipe, relocate the pipe
plug from the selected standpipe location to the air vent
location. Recoat pipe plug threads with Permatex #3 or
equivalent sealant before reinstalling.
The Falk Corporation, P.O. Box 492, Zip 53201-0492
378-102
3001 W. Canal St., Zip 53208-4200, Milwaukee, WI USA Telephone : 414-342-3131
August 2004
Fax: 414-937-4359 e-mail: [email protected] web: www.falkcorp.com
Supersedes 6-92
®
a good name in industry
Quadrive Shaft Mounted Drives
•
Appendix E
Sizes 4407/M4407-4608/M4608
(Page 37 of 52)
TABLE 1 — Dimensions – Inches (mm)
Drive Size
A
B
C
D
H.S. Shaft Down
4407
0.75 (19,1)
1.25 (31,8)
1.75 (44,5)
21.76 (552,7)
4415
0.90 (22,9)
1.40 (35,6)
1.90 (48,3)
19.62 (498,3)
4507
0.92 (23,4)
1.42 (36,1)
2.00 (50,8)
21.28 (540,5)
H.S. Shaft Up
4407
0.75 (19,1)
1.25 (31,8)
1.75 (44,5)
24.30 (617,2)
4415
1.06 (26,9)
1.56 (39,6)
2.00 (50,8)
17.70 (449,6)
4507
1.02 (25,9)
1.52 (38,6)
2.00 (50,8)
18.30 (464,8)
H.S. Shaft Up or Down
Drive Size
Output
Speed
A
B
C
D
4608
10 to 53
1.75 (44,5)
2.25 (57,2)
2.75 (69,9)
9.50 (241,3)
54 to 67
2.00 (50,8)
2.50 (63,5)
3.00 (76,2)
9.50 (241,3)
68 to 75
2.75 (69,9)
3.25 (82,6)
3.75 (95,3)
9.50 (241,3)
D
CLEARANCE
FOR DIPSTICK
REMOVAL
SCALE
STRAIGHT
EDGE
FILLER
PLUG
OIL DRAIN
X
Figure 1
D
CLEARANCE
FOR DIPSTICK
REMOVAL
X
SCALE
STRAIGHT
EDGE
FILLER
PLUG
OIL DRAIN
FELT
PAD
DIPSTICK
CAP
OIL
LEVEL
MARKS
FILE SMOOTH
X + A
X + B
X + C
FULL
LOW
Figure 2