4.9
Extra emergency button
The appliance also permits the installation of an extra external emergency button in the location required.
The electrical connection cables must be inserted through the packing gland
DSR (Fig. 3/Fig. 4
) and
connected to the terminal strip
DE (Fig. 3/Fig. 4
) on
connection
6 / 5 as for the dispensers (see
Fig.10
.).
On completion of the electrical connection, the cover of the electric panel must be replaced and secured.
4.10
Safety Locking System: Regulation with Input and/or Output benches
The machine is fitted with a safety locking system, which stops the appliance and notifies the user with a light
and acoustic signal if a blockage or impediment is detected in the feed system.
This system must be adjusted if the dishwasher has accessories such as automated input and/or output
benches which require a greater feed force than the force configured as standard, as a greater weight is carried
on the belt.
If the dishwasher has automated input and/or output benches which
require a greater feed force, the spring supplied in the kit must be
installed.
The additional spring must not be installed without checking that it is
really necessary, as this could damage the appliance.
To adjust the system first disconnect the water, using the shut-off valve, and the electricity, using the magneto-
thermal switch/ setting the mains switch
IG
(Fig. 3/Fig. 4)
to
OFF.
The system is adjusted using springs (1 or 2) mounted on the module
where the drive motor is located.
A spring and screw are supplied with the appliance.
Locate the module where the drive motor is mounted and remove the
corresponding lower front panel.
First remove the panel fastening bolts and lift the door.
Turn the front panel slightly upwards at the lower part and then
remove.
Locate the existing spring and mount the new spring in the adjacent
space. The spring which is now mounted can be released to make the
task easier. Take care not to over-tighten the bolts and break or
damage the safety lock detector switch (see circle in image below).
VERY
IMPORTANT
:
the springs must be compressed to a length
of 44 mm.
IMPORTANT: The springs must be compressed to a length of 44 mm in order to function
correctly.
This is the interior measurement. The thickness of the plates must be added if measuring