background image

1 2 3 4 5 6 7 8 9 10

11 12 13 14 15

16 17 18 19 20 21

A

B A

B

33

GEMEENSCH.

OPENT

SLUIT

RADIO

CONTROLELAMP

24 V - 3 W max

BLOKKERING

T1

WERKTIJD

1 s - 22 s

T2

PAUZETIJD

1 s - 180 s

L1

L6

L7

L3

L8

L4

L5

L2

L9

L10

L11

Secundaire

zekering

Transformator

F4 = 2A

Primaire

zekering

Transformator

F3 = 630 mA

Zekering magneetklep,

Zoemer, Knipperlicht

en Led F5 = 2 A

Zekering Motor M2

F2 = 5 A

Zekering Motor M1

F1 = 5 A

EMEENSCH.

M1

M2

EMEENSCH.

Rood

Geel

Groen

Ingang P

57 58

63   64   65   66     60   61

UITGANG 24 Vdc

+

-

55 56

TRANSFORMATOR

2

GEMEENSCH.

EINDSC

HAKELAAR OPENEN

M1 (

Paal 

verzonken

)

EINDSC

HAKELAAR OPENEN

M2 (

Paal 

verzonken

)

EINDSC

HAKELAAR SLUITEN

M1 

(Paal 

uitgeschoven)

EINDSC

HAKELAAR SLUITEN

M2 

(Paal 

uitgeschoven)

Kleem voor contact

Voetg

angersdoorgang

Motor verzink

bare paal

M1

FOTOC

ELLEN OF

MAGNETISC

HE WINDING

UITGANG 24 V 

250 mA

voor max belasting:

- n° 2 
paar 

fotocellen

- n° 

radio-ontvanger

MOTOR M1

Paal nr. 

1

MOTOR M2

Paal nr.

 2

NUL

FASE

N

F

Storingsfilter

EMEENSCH.

Elpro S20

STRIP

geleiderbrug

EINDSCHAKELAAR

ELPRO S20

Cond. 20 µF
M1

20 VA - 50/60 Hz

23

22

24 25

Cond. 20 µF

M2

STEUN VOOR
RADIO-
INSTEEKKAART

DIAGNOSE VAN DE EINDSLAGBEGRENZERS

VOEDING

REGELAAR

230 V - 50 Hz

VOOR MAGNEETKLEP

VOEDING PANEEL

230 V ±10% 50 

Hz

EENFASE

R

ood

KNIPPERLICHT

230 

V - 100 

W max

SIGNALERINGSLED

230 

V - 100 

W max

Zekering 1 A

KOPPELING VOOR STOPLICHT

MET 3 LAMPEN MAX 100W

PER LAMP

G

eel

Gr

oen

GEMEENSCH.

Voeding

230 

V - 50 H

z

(

Optie: 

Insteekkaart stoplicht

voor lampen van 230 V)
code 

7282L

Hinderingszuilen  met  eindschakelaar 

serie  Coral, Vigilo, Talos, Talos  M30,  Strabuc  930  Opinat:

  Met  het  ingestoken  STRIP  brugje  (zoals  in  de  figuur  is 

aangegeven) controleert Elpro S20 met een cyclustijd van 10 minuten of de sluitingseindslagbegrenzers (zuil in opgeheven stand) zich in de juiste positie bevinden; 

indien dit niet het geval mocht zijn, zal alleen die motor starten van de hinderingszuil die niet in de goede positie staat, totdat de juiste gestegen positie is bereikt.

Waarschuwing:

 Elke keer dat de stroomtoevoer naar 

Elpro 

S20 toe wordt hersteld, moet men 10 seconden wachten zodat de logica van de programmeereenheid weer 

opnieuw regelmatig gaat functioneren.
De programmeerinrichting Elpro S20 wordt gebruikt voor de verzinkbare pilaren serie Talos, Talos M30, Strabuc 930 Opinat, Coral en Vigilo; 
de inrichting wordt gevoed met eenfase 230 V.
Elpro S20 onderscheidt zich vanwege zijn vermogen om de installatie op eventuele defecten of storingen te controleren (CSI).

C.S.I.

 = 

C

ircuito di 

S

upervisione di 

I

ntegrità, Bewakingscircuit Integriteit, is een bijzondere functie van de programmeerinrichting Elpro S20 

voor de controle van de complete elektronische kaart, om elk defect van componenten of een storing van een accessoire van de installatie 
te detecteren, zodat als de automatisering voorzien is van een magneetklep voor ontgrendeling, de paal in de grond kan verzinken.
De fabrikant wijst alle aansprakelijkheid af voor het oneigenlijke gebruik van de programmeerinrichting; bovendien behoudt men zich het 
recht voor om zonder voorafgaande kennisgeving wijzigingen aan dit boekje en aan de programmeerinrichting aan te brengen.

BELANGRIJK VOOR EEN GOEDE INSTALLATIE EN GEBRUIK:

- De programmeerinrichting moet geïnstalleerd worden op een droge en beschermde plek. Hiervoor zijn speciale bevestigingsgaten
   aanwezig in de universele FADINI doos en het in de handel verkrijgbare kastje.
- Ga na dat de toevoer naar de elektronische programmeereenheid 230 V ±10%.
- Ga na dat de toevoer naar de Elektrische Motor 230 V ±10%.
- Voor afstanden die de 50 meter overschrijden moet de draaddoorsnede worden vergroot.
- Breng een magnetothermische differentiaalschakelaar van het type 0,03 A met hoge gevoeligheid op de voeding van de programmeerinrichting aan.
- Gebruik voor voeding, elektromotor en knipperlicht kabels met draden van 1,5 mm² tot 50 m afstand.
- Gebruik voor eindschakelaars en diverse accessoires kabels met draden van 1 mm².
N.B.: Gebruik statische relais voor toepassingen als inschakeling van lichten, camera’s, enz., om geenstoringen voor de microprocessor te produceren.

INDIEN DE INRICHTING NIET WERKT:

- Controleer of de voeding voor de elektronische programmeerinrichting 230 V ±10% is.
- Controleer of de voeding voor de elektromotor 230 V ±10% is.
- Neem voor afstanden van meer dan 50 meter een grotere draaddoorsnede.
- Controleer de zekeringen.
- Controleer of de fotocellen een gesloten contact hebben.
- Controleer alle gesloten contacten van de programmeerinrichting.
- Controleer of de eindschakelaars juist zijn aangesloten en of ze binnen komen op de print.
- Controleer, indien een magneetklep aanwezig is, de intacte toestand van alle zekeringen.
- Controleer of er geen spanningsval tussen programmeerinrichting en elektromotor is.

ON

OFF

1 2 3 4 5 6 7 8 9 10 11 12

52

51

53

SYMBOLOGIE:

NA

 contact

NC

 contact

Led 

Aan

Led 

Uit

Controlelamp
of lamp
Knipperlicht

-

+

-

+

NL

PROGRAMMEERINRICHTING VOOR MAX. 2 VERZINKBARE

PALEN MET OF ZONDER EINDSCHAKELAAR

Elpro S20

1

2

1 2

ELPRO S20

ELPRO

S20

VERS.

Summary of Contents for Elpro S20

Page 1: ...R ELEKTROVENTIL SYSTEM ZUR KONTROLLE DER INTEGRIT T I S F R EXTERNE UHR VORGESEHEN IMPULSBETRIEB TOTMANN BETRIEB PROGRAMMATORE ELETTRONICO PER LA GESTIONE FINO A 2 DISSUASORI A SCOMPARSA CON O SENZA...

Page 2: ...sura secondo quanto indicato nella normativa EN 12445 Individuare la soluzione pi indicata per eliminare o ridurre tali rischi Nel caso in cui il cancello da automatizzare fosse dotato di un ingresso...

Page 3: ...t di monitorare eventuali guasti o malfunzionamenti dell impianto CSI C S I Circuito di Supervisione di Integrit una particolare funzionalit del programmatore Elpro S20 che permette di monitorare l in...

Page 4: ...d ogni impulso di apertura L4 spento nessun contatto CHIUDE si accende ad ogni impulso di chiusura L5 acceso contatto di STOP chiuso si spegne ad ogni impulso di stop 3 3 7 4 5 6 NC NA NA COMUNE COMUN...

Page 5: ...sizione fino a raggiungimento della corretta posizione di salita 11 12 13 14 15 COMUNE FINECORSA APERTURA M1 Colonna abbassata FINECORSA CHIUSURA M1 Colonna alzata FINECORSA APERTURA M2 Colonna abbass...

Page 6: ...di movimento di salita e discesa all interno della colonna a scomparsa Uscita per cicalino di movimento 230 V 100 W max Alimentazione quadro 230 V 10 50 Hz monofase BLU COMUNE NERO FASE F N NEUTRO 52...

Page 7: ...ssuasore n 1 motore M1 per passaggio pedonale del tempo di pausa impostato sul trimmer T2 scaduto il quale richiude automaticamente La funzione apertura pedonale non attiva durante il primo ciclo di f...

Page 8: ...essary to eliminate and reduce such risks In case where the gate to automate is equipped with a pedestrian entrance it is appropriate to prepare the system in such a way to prohibit the operation of t...

Page 9: ...igilo power supply is 230 V single phase Elpro S20 is capable of monitoring damages or malfunctioning with the system ISC I S C Integrity and Supervision Circuit is a special function of Elpro S20 whi...

Page 10: ...goes on whenever an opening pulse is given L4 OFF no CLOSING contact it goes on whenever a closing pulse is given L5 ON STOP contact closed it goes off whenever a stop pulse is given 3 3 7 4 5 6 NC N...

Page 11: ...perated until this is fully up as required 11 12 13 14 15 COMMON LIMIT SWITCH OPEN M1 Post in down position LIMIT SWITCH CLOSE M1 Post in up position LIMIT SWITCH OPEN M2 Post in down position LIMIT S...

Page 12: ...tion wires are the blue common and the black one of the flashing light cable Acoustic signal device 230 V 100 W max PCB power supply 230 V 10 50 Hz single phase BLUE COMMON BLACK LIVE F N NEUTRAL 52 5...

Page 13: ...in up position on pulsing input P dip switch 6 ON and 3 ON post n 1 motor M1 goes down for pedestrian opening for the time pre set inTrimmer T2 after this time it closes automatically The function pe...

Page 14: ...nt aux normes EN 12445 D finir les solutions appropri es pour liminer ou r duire tels risques Dans le cas o le portail automatiser aurait dou d une entr e pi tonne il serait bon d accomplir l installa...

Page 15: ...nement de l installation CSI Le C S I Circuit de Supervision d Integrit est une fonction particuli re du programmateur Elpro S20 avec laquelle il peut contr ler toute la carte lectronique dans le but...

Page 16: ...res magnetiques L3 teinte aucun contact OUVRE s allume chaque impulsion d ouverture L4 teinte aucun contact FERME s allume chaque impulsion de fermeture L5 allum e contact d ARRET ferm s teint chaque...

Page 17: ...e escamotable pas en position jusqu la position correcte de mont e 11 12 13 14 15 COMMUN FIN DE COURSE OUVERTURE M1 Borne esc baiss e FIN DE COURSE FERMETURE M1 Borne esc lev e FIN DE COURSE OUVERTURE...

Page 18: ...tion tableau 230 V 10 50 Hz monophas BLEU COMMUN NOIR PHASE F N NEUTRE 52 51 53 Alimentation carte programmateur 23 22 24 25 Lampe clignotante externe On peut raccorder soit la lampe clignotante exter...

Page 19: ...sage pi tons se baisse pour le temps de pause tabli sur le trimmer T2 Expir ce temps la borne escamotable se l ve automatiquement La fonction ouverture pi tonne n est pas actif pendant le premier cycl...

Page 20: ...ung von Schlag und Druck der Vorderkante des ffnen und Schlie en wie in EN 12445 festgelegt Identifizieren Sie die beste L sung zur Beseitigung oder Verringerung dieser Risiken In dem Fall wo das Tor...

Page 21: ...es ist eine besondere Funktion der Elpro S20 Steuerung um das gesamte elektronische Modul zu berwachen um eventuelle Defekte seiner Komponenten oder eine St rung eines Zubeh rteils der Anlage zu erke...

Page 22: ...sie leuchtet bei jeder ffnungsimpulsgabe L4 AUS kein Kontakt SCHLIESSUNG sie leuchtet bei jeder Schliessungskontakt L5 AN STOP Kontakt geschlossen sie erlischt bei jeder Stop Impulsgabe 3 3 7 4 5 6 NC...

Page 23: ...n Ausfahrtposition anlaufen 11 12 13 14 15 COMMON ENDSCHALTER FFNEN M1 Poller eingefahren ENDSCHALTER SCHLIE EN M1 Poller ausgefahren ENDSCHALTER FFNEN M2 Poller eingefahren ENDSCHALTER SCHLIE EN M2 P...

Page 24: ...V 100 W max Stromversorgung Schalttafel 230 V 10 50 Hz Einphasig BLAU COMMON SCHWARZ PHASE F N NEUTRAL 52 51 53 Stromversorgung der elektronischen Steuerplatine 23 22 24 25 Externe Blinkleuchte Man ka...

Page 25: ...pollers Nr 1 Motor M1 f r den Fu g ngerdurchgang so lange wie die Pausezeit auf dem Trimmer T2 eingestellt worden ist nachdem diese Zeit abgelaufen ist wird wieder automatisch geschlossen Nach einem S...

Page 26: ...ma EN 12445 Identificar la mejor soluci n para eliminar o reducir estos riesgos En el caso en el que la puerta para automatizar estaba equipada con una entrada de peatones es apropiado para preparar e...

Page 27: ...la capacidad de monitorear posibles aver as o malfuncionamientos del equipo CSI C S I Circuito de Supervisi n de Integridad es una funci n especial del programador Elpro S20 que permite monitorear to...

Page 28: ...apagado nig n contacto CIERRE se encendie cada impulso de cierre L5 encendido contacto de STOP cerrado se apaga cada impulso de stop 3 3 7 4 5 6 NC NA NA COM N COM N 3 8 COM N CONTACTO RADIO ABRE CIER...

Page 29: ...alcance la posici n correcta de subida 11 12 13 14 15 COM N FINAL DE CARRERAABERTURA M1 Columna baja FINAL DE CARRERA CIERRE M1 Columna levantada FINAL DE CARRERAABERTURA M2 Columna baja FINAL DE CAR...

Page 30: ...ra de movimiento de subida y bajada dentro de la columna escamoteable Salida para el zumbador de movimiento 230 V 100 W max Alimentaci n cuadro 230 V 10 50 Hz monof sico AZUL COM N NEGRO FASE F N NEUT...

Page 31: ...olumna de la barrera n 1 motor M1 para el paso peatonal del tiempo de pausa programado en elTrimmerT2 pasado el cual se cierra autom ticamente La funci n abertura peatonal no es activa durante el prim...

Page 32: ...ecessary to eliminate and reduce such risks In case where the gate to automate is equipped with a pedestrian entrance it is appropriate to prepare the system in such a way to prohibit the operation of...

Page 33: ...ie op eventuele defecten of storingen te controleren CSI C S I Circuito di Supervisione di Integrit Bewakingscircuit Integriteit is een bijzondere functie van de programmeerinrichting Elpro S20 voor d...

Page 34: ...he windingen L3 uit geen OPENT contact gaat aan bij elk openingsimpuls L4 uit geen SLUIT contact gaat aan bij elk sluitingsimpuls L5 aan STOP contact gesloten gaat uit bij elk stopimpuls 3 3 7 4 5 6 N...

Page 35: ...ositie is bereikt 11 12 13 14 15 EMEENSCH EINDSCHAKELAAR OPENEN M1 Paal verzonken EINDSCHAKELAAR SLUITEN M1 Paal uitgeschoven EINDSCHAKELAAR OPENEN M2 Paal verzonken EINDSCHAKELAAR SLUITEN M2 Paal uit...

Page 36: ...wordt het geluidssignaal bij de op en neergaande beweging in de paal geactiveerd Uitgang voor zoemer die beweging meldt 230 V 100 W max Voeding paneel 230 V 10 50 Hz eenfase BLAUWE GEMEENSCH ZWART FA...

Page 37: ...auzetijd is ingesteld opTrimmerT2 Na afloop van deze tijd gaat de doorgang automatisch dicht De voetgangersdoorgang is niet actief tijdens de eerste cyclus van de werking naast een gebrek van de voedi...

Page 38: ...Elpro S20 38...

Page 39: ...e 20 C 55 C Alimentation lectrovanne 230 V 50 Hz Sortie avertisseur sonore de mouvement 230 V 100 W max F TECHNISCHE DATEN Einphasige Karte Stromversorgung 230 V 10 50 Hz Dreiphasige Karte Stromversor...

Page 40: ...dini net www fadini net I Direttiva 2012 19 UE Smaltimento dei materiali elettrici ed elettronici VIETATO GETTARE NEI RIFIUTI MATERIALI NOCIVI PER L AMBIENTE GB Directive 2012 19 UE Disposal of electr...

Reviews: