ELECTRICAL POWER CONNECTIONS
Accessory
Electrical connections
Dip-switch setting and LED indication of functions
11
Motors:
Standard limit switch:
Important:
when doing the electric power connections it is better to
connect only one motor and its respective limit switches.
Put the posts into phase one by one.
16 17 18
A
B
M1
COMMON
MOTOR M1
Post n° 1
20 µF additional capacitor
in case of power shortage
for Motor M1
19 20 21
A
B
M2
COMMON
MOTOR M2
Post n° 2
20 µF additional capacitor
in case of power shortage
for Motor M2
ON
: motor run time max 90 s
OFF
: motor run time max 18 s
DIP-SWITCH N° 12:
12
-
+
T1
MOTOR RUN
TIME
1 s - 22 s
-
+
T2
DWELL
TIME
1 s - 180 s
•
Talos
range
- Talos M30
•
Coral - Vigilo with LEDs
range
•
Strabuc 930 Opinat
With the STRIP jumper inserted (as in the picture),
Elpro S20 checks cyclicly every 10 minutes that the
closing limit switches (post raised) are in the
correct position; should any of them fail to be
such, only the motor of the post not in position is
operated until this is fully up as required.
11 12 13 14 15
COMMON
LIMIT SWITCH OPEN M1
(Post in down position)
LIMIT SWITCH CLOSE M1
(Post in up position
)
LIMIT SWITCH OPEN
M2
(Post in down position
)
LIMIT SWITCH CLOSE
M2
(Post in up position
)
New limit switches hall effect
as standard from 2018
•
Talos
range
- Talos M30
With the STRIP jumper inserted (as in the picture),
Elpro S20 checks cyclicly every 10 minutes that the
closing limit switches (post raised) are in the
correct position; should any of them fail to be
such, only the motor of the post not in position is
operated until this is fully up as required.
11 12 13 14 15
LIMIT SWITCH OPEN M1
g
ra
y
ca
b
le
- w
h
ite wir
e
LIMIT SWITCH CL
OSE
M1
blue ca
ble - wh
it
e wir
e
LIMIT SWITCH OPEN
M2
g
ra
y
ca
b
le
- w
h
ite wir
e
LIMIT SWITCH CL
OSE
M2
blue ca
ble - wh
it
e wir
e
55 56
LIMIT SWITCH
+24
V
dc
blue and g
ra
y cables - br
o
wn wir
es
GROUND LIMIT SWITCH
blue and g
ra
y cables - g
reen wir
es
+ -
!
N.W.: the limit switches for not in
use bollards are to stay blank.
Do not bridge them.
N.W.: the limit switches for not in
use bollards are to stay blank.
Do not bridge them.
GB
Elpro S20
ELECTRONIC CONTROLLER UP TO 2 AUTOMATIC BOLLARDS,
WITH OR WITHOUT LIMIT SWITCH