29

ENGLISH

FUNCT.NO.

LEDS

FUNCTIONS

LED 6

1

2

3

4

5

0

OFF OFF OFF OFF OFF

Output Level III

OFF

1

ON

OFF OFF OFF OFF

One-way with lock active

OFF

One-way with lock inactive

ON

2

OFF

ON OFF OFF OFF

NIGHT function (terminal 3-960MP)

OFF

ONE-WAY function (terminal

ON

3-960MP)

3

ON

ON OFF OFF OFF

Gong output (terminal 24-960MP)

OFF

Interlock output (terminal 24-960MP)

ON

4

OFF OFF ON OFF OFF

SLAVE (interlock)

OFF

MASTER (interlock)

ON

5

ON

OFF ON OFF OFF

Emergency closing (terminal

OFF

11-960MP)

Emergency opening (terminal

ON

11-960MP)

6

OFF

ON ON OFF OFF

Emergency command - N.C.

OFF

contact (terminal 11-960MP)

Emergency command - N.O.

ON

contact (terminal 11-960MP)

7

ON

ON ON OFF OFF

CODIS - temporary connection

OFF

CODIS - permanent installation

ON

8

OFF OFF OFF ON OFF

15 kg static force

OFF

9 kg static force

ON

9

ON

OFF OFF ON OFF

CODIS inhibited inactive

OFF

CODIS inhibited active

ON

10

OFF

ON OFF ON OFF

Standard opening pause time

OFF

Immediate closing

ON

11

ON

ON OFF ON OFF

Door open/closed indication - N.O.

OFF

contact (terminals 18/19-960MP)

Door open/closed indication - N.C.

ON

contact (terminals 18/19-960MP)

12

OFF OFF ON ON OFF

Alarm warning - N.O.

OFF

contact (terminal 21-960MP)

Alarm warning - N.C.

ON

contact (terminal 21-960MP)

13

ON

OFF ON ON OFF

“Double swing door” output inactive

OFF

“Double swing door” output

ON

active (terminal 23-960MP)

14

OFF

ON ON ON OFF

SLAVE (double swing door)

OFF

MASTER (double swing door)

ON

15

ON

ON ON ON OFF

Restore STANDARD settings

OFF

Retain programmed settings

ON

16

OFF OFF OFF OFF ON

Opening commands stored

OFF

(interlock)

Opening commands not stored

ON

(interlock)

17

ON

OFF OFF OFF ON

TEST programme inactive

OFF

TEST programme active

ON

18

OFF

ON OFF OFF ON

Level II RESET active

OFF

Level II RESET inactive

ON

19

ON

ON OFF OFF ON

STANDARD internal command

OFF

(terminal  9-960MP)

STEP-BY-STEP internal command

ON

(terminal 9-960MP)

When the “-” pushbutton is pressed, the door speed,
opening excursion and pause time are decreased.

4)

Return to Level I (operating functions) by pressing the “+”
and “-” pushbuttons

 simultaneously

.

Notes:

- The CODIS automatically returns to Level I after 2

minutes of inactivity.

- To prevent the settings from returning to standard

values after a RESET or a voltage drop, “protect” the
programmed values by activating function 18 at
Level III (see paragraph 8.3).

8.3. LEVEL: III - PROGRAMMING FUNCTIONS

The CODIS has a programming level where certain functions
can be selected.
These functions are required for several special applications.

Note: 

a voltage drop or a RESET command will not cancel the

programming on Level III.
Standard programming can be restored by means of function
15 (see Table 7).
To access Level III, proceed as follows:
1)

Select the 

NIGHT

 operating function by causing LED 1 to

light up. Press the “+” pushbutton to move the lighting of
the LEDs one position up. Press the “-” pushbutton to move
the lighting of the LEDs one position down.

2)

Press the “+” and “-” pushbuttons 

simultaneously

 for about

2 seconds

, until the red 

ERROR

 LED lights up.

3)

Enter the access code by pressing the “+” and “-”
pushbuttons in the following sequence: “

+ + + - - + + +

”.

Note: 

after the lighting up of the red ERROR LED, if the code is

not entered 

within 10 seconds

 the CODIS will automatically

return to Level I.
4)

.Select the function to be programmed by pressing the “+”
or “-” pushbutton so as to obtain the combination of lit LEDs
indicated in Table 7.

5)

Press the “+” and “-” pushbuttons 

simultaneously

 to activate

or deactivate the function, and check the status of LED 6,
according to the indications of Table 7.

Note

: the standard programming is the one with LED 6 unlit

(OFF).
6)

To return to Level I (operating functions), 

repeatedly 

 press

the “-” pushbutton until all the six LEDs are off, then press
the “+” and “-” pushbuttons

 simultaneously

.

Note

: the CODIS will automatically return to Level I after 2

minutes of inactivity.

8.3.1. AVAILABLE FUNCTIONS

function 1

One-way with lock activated: in the ONE-WAY operating
function, the closed door is locked by the electric lock.

One-way with lock deactivated: in the ONE-WAY operating
function, the closed door is not locked by the electric lock.

function 2

NIGHT function: the activation of the input between terminals
2 and 3 (960MP) selects the NIGHT operating function, 

with

priority

 over the function selected on the CODIS.

ONE-WAY function: the activation of the input between
terminals 2 and 3 (960MP) selects the ONE-WAY operating
function, 

with priority

 over the function selected on the CODIS.

The control panel will show which function has been selected,
by means of the lighting up of LED 1 or 2.
When the input is deactivated, the operating function
previously selected on the CODIS  returns automatically.

function 3

Gong output: the operation of the closing safety device
activates the 24 Vdc output between terminals 14 and 24
(960MP) for 1 second, at intervals of 0.5 seconds.

 Table 7: programming functions

Summary of Contents for 961 B-E

Page 1: ...ubsequent amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent ame...

Page 2: ...with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 12 Ensure that there is a differential switch up line of the electrica...

Page 3: ...automatic unit for swing doors is a one piece unit consisting of an electromechanical device that allows door opening to be controlled by means of a driving arm The door is re closed by a spring syst...

Page 4: ...the operator transmission shaft by means of the extension and the screw 4 provided fig 5 The arm must be mounted perpendicular to the closed door N B If a greater distance between the operator and the...

Page 5: ...nitialisation procedure which includes setting the following parameters measuring the mass of the door determining the end stop positions determining the point at which the STOP safety device interven...

Page 6: ...buzzer which emits sequences of acoustic signals corresponding to different statuses of the system The statuses that have occurred and their identification sequence can be seen in Table 6 Table 6 Aco...

Page 7: ...contacts 11 12 13 14 15 16 EMERGENCY CLOSURE OPENING STOP SAFETY CLOSURE SAFETY 24 Vdc 0 Vdc 0 Vdc INTERNAL COMMAND 0 Vdc 8 9 10 EXTERNAL COMMAND 0 1 2 230 V 6 10 50 60 Hz 1 2 3 white brown green 0 V...

Page 8: ...then re closes after the pause time POSITION 0 MANUAL NIGHT The position 0 can be used to select two different operating functions according to the programming carried out on the 961 B E programming u...

Page 9: ...mme and monitor the operation of the system If the CODIS is used permanently it is necessary to activate function 7 at Level III programming functions see paragraph 8 3 For the electrical connection o...

Page 10: ...L III PROGRAMMING FUNCTIONS The CODIS has a programming level where certain functions can be selected These functions are required for several special applications Note a voltage drop or a RESET comma...

Page 11: ...n N O contact terminals 18 19 960MP Door open closed indication N C contact the open and closed positions of the door are indicated by the opening of a N C contact terminals 18 19 960MP function 12 Al...

Page 12: ...the inner door LED 6 lights up select the SLAVE option on the CODIS unit of the outer door LED 6 goes out Function 16 select the desired option on both the CODIS programming units IMPORTANT the interl...

Page 13: ...th the door closed draw a vertical line on the spring as shown in figure 30 Open the door and check the state of the line figure 30 shows two possible configurations In case B fig 30 lubricate the spr...

Page 14: ...mains open o LED 4 AUTOMATIC The door opens when internal or external commands are active and re closes after the pause time o LED 3 AUTOMATIC SPARE o LED 2 ONE WAY Entry or exit inhibited only one di...

Reviews: