background image

22

ENGLISH

Table 2: Technical specifications of 960MP Electronic Control

Unit + 961 B-E Programming unit

Power supply

230 Vac (+6 -10%) - 50 (60) Hz

Accessories power supply

24 Vdc / 500 mA max.

Electric lock power supply (N.O./N.C.)

24 Vdc / 0.5 A max.

Standard operating functions (switch)

Open / Automatic / Manual

(Night)

Adjustable functions (trimmer)

 Opening speed - Closing speed

Pulling force - Pause time

Selectable functions (microswitches)

Overclosing stroke

Standard/non-standard initialisation procedure

Push and Go - Function switch (pos. “0”)

Terminal strip outputs

Door open/closed signal -

Malfunction alarm signal-

24 Vdc electric lock power supply

 (N.O./N.C.) - 24 Vdc accessories power supply -

Presence signal (gong) - PC connection signals -

“Interlock” signals - “Double leaf door” signals

Terminal strip inputs

Function switch/CODIS (optional) -

Internal / external / emergency /

STOP safety device / CLOSURE safety device

1.1 APPLICATION LIMITS

Important

: To ensure correct application of the FAAC 961 B-E

unit the weight of the door must not exceed the value given in
Table 3 corresponding to its length.
The maximum length of the leaf is 1400 mm.
The values of maximum weight vary according to the driving
arm used.
For each driving arm there is also a different maximum value for
the depth of the doorpost (Table 4) beyond which it is not
possible to install the system correctly.

Table 3: Application limits of 961 B-E automatic unit

700

367

286

-

750

320

249

-

800

281

219

-

850

249

194

194

900

222

173

173

950

199

155

155

1000

180

140

140

1050

163

127

127

1100

149

116

116

1150

136

106

106

1200

125

97

97

1250

115

90

90

1300

107

83

83

1350

99

77

77

1400

92

71

71

Table 4: Max. depth of doorpost

mm

FAAC 961 B-E

The 961 B-E automatic unit for swing doors is a one-piece unit
consisting of an electromechanical device that allows door
opening to be controlled by means of a driving arm. The door
is re-closed by a spring system.
The operator can be installed either on the lintel or on the door
structure itself.
The stainless steel protective casing houses the electronic
control unit used to program and control the operation of the
system.
In the event of a power failure the door can be pushed (or
pulled) open manually.

1. DESCRIPTION AND TECHNICAL CHARACTERISTICS

Sliding arm

0 - 125

126 - 250

0 - 160

0 - 160

Pulling

articulated

arm

Pushing

articulated

arm (Var. 02)

Table 1: Technical specifications of 961 B-E Operator

Power supply

230 Vac (+6 -10%) - 50 (60) Hz

Absorbed power

100 W

Current drawn

0.5 A

Electric motor

24 Vdc with encoder

Dimensions

 

530 x 100 x 104 (length x height x depth)

Weight

10 kg

Ambient temperature

-15 +70 

°

C

Housing protection

IP 23

Dimensions and max. weight of leaf

see Table 3 (section 1.1)

Duty cycle

continuous

Operation in event of power failure

Manual push/pull opening -

Spring closure

Configuration of driving arms

• pushing articulated arm

(version for jamb depth 0-125 mm)

• pushing articulated arm - (version for jamb depth

126-250 mm) • pulling articulated arm • sliding arm

Anti-crushing device

standard

Opening angle

70-95

°

Opening time

3.5 - 10 s (adjustable)

Closing time

6 - 13 s (adjustable)

Max. weight of leaf

(kg)

Pulling articulated

arm

Max. weight of leaf

(kg)

Sliding arm

Pushing

articulated

arm (Var. 01)

3

1

2

6

7

13

12

11

10

9

8

5

4

a

Cable hole

b

Support profile

c

960 MP electronic control unit

d

Position monitoring microswitch

e

Spring loading adjustment screw

f

Transmission shaft

g

Drive system

h

DC motor

i

961 B-E programming unit

j

Closing spring

k

Protective casing

l

Operating function switch

m

End cover (2)

Fig. 1

Length of leaf

 (mm)

Max. weight of leaf

(kg)

Pushing articulated

arm

Summary of Contents for 961 B-E

Page 1: ...ubsequent amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent ame...

Page 2: ...with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 12 Ensure that there is a differential switch up line of the electrica...

Page 3: ...automatic unit for swing doors is a one piece unit consisting of an electromechanical device that allows door opening to be controlled by means of a driving arm The door is re closed by a spring syst...

Page 4: ...the operator transmission shaft by means of the extension and the screw 4 provided fig 5 The arm must be mounted perpendicular to the closed door N B If a greater distance between the operator and the...

Page 5: ...nitialisation procedure which includes setting the following parameters measuring the mass of the door determining the end stop positions determining the point at which the STOP safety device interven...

Page 6: ...buzzer which emits sequences of acoustic signals corresponding to different statuses of the system The statuses that have occurred and their identification sequence can be seen in Table 6 Table 6 Aco...

Page 7: ...contacts 11 12 13 14 15 16 EMERGENCY CLOSURE OPENING STOP SAFETY CLOSURE SAFETY 24 Vdc 0 Vdc 0 Vdc INTERNAL COMMAND 0 Vdc 8 9 10 EXTERNAL COMMAND 0 1 2 230 V 6 10 50 60 Hz 1 2 3 white brown green 0 V...

Page 8: ...then re closes after the pause time POSITION 0 MANUAL NIGHT The position 0 can be used to select two different operating functions according to the programming carried out on the 961 B E programming u...

Page 9: ...mme and monitor the operation of the system If the CODIS is used permanently it is necessary to activate function 7 at Level III programming functions see paragraph 8 3 For the electrical connection o...

Page 10: ...L III PROGRAMMING FUNCTIONS The CODIS has a programming level where certain functions can be selected These functions are required for several special applications Note a voltage drop or a RESET comma...

Page 11: ...n N O contact terminals 18 19 960MP Door open closed indication N C contact the open and closed positions of the door are indicated by the opening of a N C contact terminals 18 19 960MP function 12 Al...

Page 12: ...the inner door LED 6 lights up select the SLAVE option on the CODIS unit of the outer door LED 6 goes out Function 16 select the desired option on both the CODIS programming units IMPORTANT the interl...

Page 13: ...th the door closed draw a vertical line on the spring as shown in figure 30 Open the door and check the state of the line figure 30 shows two possible configurations In case B fig 30 lubricate the spr...

Page 14: ...mains open o LED 4 AUTOMATIC The door opens when internal or external commands are active and re closes after the pause time o LED 3 AUTOMATIC SPARE o LED 2 ONE WAY Entry or exit inhibited only one di...