background image

21

ENGLISH

IMPORTANT NOTICE FOR THE INSTALLER

GENERAL SAFETY REGULATIONS

1) WARNING!

 

FAAC strongly recommends to follow these instructions literally for the safety of persons. Improper

installation or misuse of the product will cause very serious damages to persons.

2) Packaging material (plastic, polystyrene etc.) is a potential hazard and must be kept out of reach of children.

3) Read the instructions carefully before installing the product.

4) Keep these instructions for future reference.

5) This product has been designed and manufactured only for the use stated in this manual. Any other use not expressly

set forth will affect the reliability of the product and/or could be source of hazard.

6) FAAC S.p.A. cannot be held responsible for any damage caused by improper use or different from the use for which

the automation system is destined to.

7) Do not use this device in areas subject to explosion: the presence of flammable gas or fumes is a serious hazard.

8) Mechanical constructive elements must comply with CEN pr EN 12650-1 and CEN pr EN 12650-2 standards.

Countries outside the EC shall follow the regulations above besides their national normative references in order to offer
the utmost safety.

9) FAAC cannot be held responsible for failure to observe technical standards in the construction of gates and doors,

or for any deformation of the gates which may occur during use.

10) Before carrying out any operations, turn off the system’s main switch.

11) An omnipower switch shall be provided for the installation with an opening distance of the contacts of 3 mm or more.

Alternatively, use a 6A thermomagnetic breaker with multi-pole switching.

12) Ensure that there is a differential switch up-line of the electrical system, with a trip threshold of 0.03A.

13) Check that the earthing plant is in perfect condition and connect it to the metallic parts. Also earth the yellow/green

wire of the operator.

14) The automation is fitted with an anti-crush safety system that is a torque control device. In any case, further safety

devices shall be installed.

15) The safety devices (e.g. photocells, safety edges, etc.) protect areas wherethere is a mechanical movement hazard,

e.g. crushing, entrapment and cutting.

16) Each installation must be fitted with at least one warning plate suitably fixed to the gate, besides the safety devices

as per point 15. above.

17) FAAC cannot be held responsible regarding safety and correct functioning of the automation in the event that parts

other than FAAC original parts are used.

18) Use only FAAC original spare parts for maintenance operations.

19) Do not carry out any modifications to automation components.

20) The installer must supply all information regarding manual operation of the system in the event of an emergency and

provide the end-user with the leaflet attached to the product.

21) Keep out of persons when the product is in operation.

22) Keep out of reach of children the remote radio controls and any control devices. The automation could be operated

unintentionally.

23) The end-user must avoid any attempt to repair or adjust the automation personally. These operations must be carried

out exclusively by qualified personnel.

24) What is not explicitly stated in these instructions is not permitted.

Summary of Contents for 961 B-E

Page 1: ...ubsequent amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent ame...

Page 2: ...with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 12 Ensure that there is a differential switch up line of the electrica...

Page 3: ...automatic unit for swing doors is a one piece unit consisting of an electromechanical device that allows door opening to be controlled by means of a driving arm The door is re closed by a spring syst...

Page 4: ...the operator transmission shaft by means of the extension and the screw 4 provided fig 5 The arm must be mounted perpendicular to the closed door N B If a greater distance between the operator and the...

Page 5: ...nitialisation procedure which includes setting the following parameters measuring the mass of the door determining the end stop positions determining the point at which the STOP safety device interven...

Page 6: ...buzzer which emits sequences of acoustic signals corresponding to different statuses of the system The statuses that have occurred and their identification sequence can be seen in Table 6 Table 6 Aco...

Page 7: ...contacts 11 12 13 14 15 16 EMERGENCY CLOSURE OPENING STOP SAFETY CLOSURE SAFETY 24 Vdc 0 Vdc 0 Vdc INTERNAL COMMAND 0 Vdc 8 9 10 EXTERNAL COMMAND 0 1 2 230 V 6 10 50 60 Hz 1 2 3 white brown green 0 V...

Page 8: ...then re closes after the pause time POSITION 0 MANUAL NIGHT The position 0 can be used to select two different operating functions according to the programming carried out on the 961 B E programming u...

Page 9: ...mme and monitor the operation of the system If the CODIS is used permanently it is necessary to activate function 7 at Level III programming functions see paragraph 8 3 For the electrical connection o...

Page 10: ...L III PROGRAMMING FUNCTIONS The CODIS has a programming level where certain functions can be selected These functions are required for several special applications Note a voltage drop or a RESET comma...

Page 11: ...n N O contact terminals 18 19 960MP Door open closed indication N C contact the open and closed positions of the door are indicated by the opening of a N C contact terminals 18 19 960MP function 12 Al...

Page 12: ...the inner door LED 6 lights up select the SLAVE option on the CODIS unit of the outer door LED 6 goes out Function 16 select the desired option on both the CODIS programming units IMPORTANT the interl...

Page 13: ...th the door closed draw a vertical line on the spring as shown in figure 30 Open the door and check the state of the line figure 30 shows two possible configurations In case B fig 30 lubricate the spr...

Page 14: ...mains open o LED 4 AUTOMATIC The door opens when internal or external commands are active and re closes after the pause time o LED 3 AUTOMATIC SPARE o LED 2 ONE WAY Entry or exit inhibited only one di...

Reviews: