Page 2: ...ounting Instructions 10 15 Edge Sensor Contact Sensor Installation 16 Important Safety Instructions 17 Maintenance Instructions 18 Types of Installations 19 Installation Electronic Controller Mounting 20 Electrical Installation 21 Installation Primary Secondary Connections 22 Installation Loop Rack 23 Installation Selectable Features 24 25 Installation Selectable Features Solar Installation 26 Ins...

Page 3: ...ver 2 Gate Attachment 3 Intermediate Drive Arm 4 Manual Release Mechanism 5 Manual Release Key 6 Secondary Drive Arm 7 Primary Drive Arm with Hardware 8 Gearmotor Assembly 9 Casing with Hardware 10 Ball Bearing 11 Plastic Gap Filler 12 Cover Holder Hardware 13 Positive Stop Hardware Open 14 Warning Placard 4 2 4 4 11 2 1 1 2 4 5 8 9 14 3 13 10 6 7 1 2 3 4 5 6 7 8 9 11 10 www BrushlessGateOpeners c...

Page 4: ...emergency release only when the gate is not moving 6 KEEP GATES PROPERLY MAINTAINED Read the owner s manual Have a qualified service person make repairs to gate hardware 7 The entrance is for vehicles only Pedestrians must use separate entrance 8 SAVE THESE INSTRUCTIONS Important Safety Instructions WARNING to reduce the risk of injury or death Maximum Gate Weight 700 lbs Maximum Gate Length 12 fe...

Page 5: ... not required to cover both directions A combination of one Type B1 for one direction and one Type B2 for the other direction is the equivalent of one device for the purpose of complying with the requirements of either the primary or secondary entrapment protection areas a Entrapment Protection Types Type A Inherent entrapment protection system Type B1 Provision for connection of supplied with a n...

Page 6: ...to compensate for a damaged gate e For gate operators utilizing Type D protection 1 The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving 2 The placard equivalent to the following To reduce the risk of electric shock the operator power is to be provided from a weatherproof outlet in the case of attachment plug connection or weatherproof j...

Page 7: ...sors shall be located at the pinch point of a vehicular vertical pivot gate 4 A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage 5 A wireless device such as one that transmits radio frequency RF signals to the gate operator for entrapment protection functions shall be located w...

Page 8: ...service the general public COMMERCIAL GENERAL ACCESS VEHICULAR GATE OPERATOR CLASS II A vehicular gate operator or system intended for use in a commercial location or building such a multi family housing unit five or more single family units hotel garages retail store or other building servicing the general public RESTRICTED ACCESS VEHICULAR GATE OPERATOR CLASS IV A vehicular gate operator or syst...

Page 9: ...device photo beam or like for detail information about the usage installation and maintenance Edge Sensor TX EMX Model IRB 325 Shown Connection 1 C1 Connection 2 NC1 Gate in Open Position Photo Beam Unit Reflector Area Shaded NON CONTACT SENSORS PHOTOELECTRIC SENSORS INSTALLATION Use one or more non contact sensors shall be located where the risk of entrapment or obstruction exists such as the per...

Page 10: ...6SBL Insert the lock release key in the lock and rotate by 180o Release any electric look Manually open the gate To block the door wings again rotate the lock release lever or key by 180o Move the door wing manually until it is completely reattached www BrushlessGateOpeners com 800 878 7829 Sales BrushlessGateOpeners com ...

Page 11: ...enter surface of the mounting pole This line should be perpendicular to the mounting pole surface and the center of the upper hinge should point directly perpendicular to this line min 2 56 0 2 Unit Casing Hinge Upper Hinge Flexible Drain Pipe Metal Pipe To ECU Main Board 6 60 2 25 16 6 2 56 13 6 Ø1 38 R1 28 1 1 Ø1 38 06 Step1 2 3 4 5 6 7 8 Mounting Instructions www BrushlessGateOpeners com 800 87...

Page 12: ... lower hinge center point is aligned with the upper hinge center point STEP 5 Connect a metal pipe from the unit chassis to the junction box that can put on the mounting pole It is a good practice to put the junction box high enough to prevent water get into inside the box in a storm season max 110 Digging Area 26 61 x14 48 14 48 26 61 GEARMOTOR Step 3 1 7 7 3 2 5 4 6 7 7 6 Mounting Instructions w...

Page 13: ...ing the concrete to fill the area around the chassis The top surface of the concrete should be 0 2 below the top edge of the chassis Double check the chassis to make sure tit is still level and the hinges are still aligned to each other If you want to add one more lower hinge to the gate Please make sure all three hinges are aligned to each other STEP 9 Mount the gear motor to the chassis correctl...

Page 14: ...STEP 12 Put the gate attachment bracket E to the Intermediate Drive Arm D Next Mount the gate on the hinges and check the alignment with the hinges to make sure everything is correct Then weld the gate attachment to the gate STEP 13 Lock the gate with the unit by rotating the manual release handle to the Step 10 11 12 Step 13 Step 13 Mounting Instructions www BrushlessGateOpeners com 800 878 7829 ...

Page 15: ... black blue to blue min 2 56 0 2 Unit Casing Hinge Drainage Hose Electrical Wires To Main Board Electrical Box Unit needs to sit on flat level Upper hinge needs to line up with unit casing hinge Step 14 6 60 2 25 16 6 2 56 13 6 Ø1 38 R1 28 1 1 Ø1 38 06 Mounting Instructions www BrushlessGateOpeners com 800 878 7829 Sales BrushlessGateOpeners com ...

Page 16: ... the close position D Move the Limit Switch Cams on the Cam Wheel to actuate each limit switch E Slightly tighten the screw on the Limit Switch Cam F Using open stop buttons on the control board to move the gate to open position Repeat step D and E to setup open limit cam G Run the unit 2 full cycles without interruption from limit to limit to execute a Learn Cycle GATE OPENS TO RIGHT Left Limit S...

Page 17: ...t in its arc of travel one or more contact sensors shall be located on the bottom edge 1 A hardwired contact sensor shall be located and its wiring arranged so that the communication between 2 A wireless contact sensor such as one that trans mits radio frequency RF signals to the gate oper ator for entrapment protection functions shall be located where the transmission of the signals are not obstr...

Page 18: ...e gate operator Failure to adjust and retest the gate operator properly can increase the risk of injury or death 5 Use the emergency release only when the gate is not moving 6 KEEP GATES PROPERLY MAINTAINED Read the owner s manual Have a qualified service person make repairs to gate hardware 7 The entrance is for vehicles only Pedestrians must use separate entrance 8 SAVE THESE INSTRUCTIONS Import...

Page 19: ...ctions programming repair and modifications must be done by a qualified professional gate operator installer End users home owners must call a qualified professional gate operator installer for programming changes repairs and modifications Although all Platinum Access Systems gate operators are virtually maintenance free to an end user home owner minimal maintenance is recommended to ensure a smoo...

Page 20: ... Level mechanism kit Lever operated release kit 7 Photocells A Connect the power supply to an approved omnipolar switch with an opening distance of the contacts of at least 3mm not supplied The connection to the mains must be made via an independent channel separated from the connections to command and safety devices NOTE The given operating and performance features can only be guaranteed with the...

Page 21: ...trol box Disconnect the connector from the Main Board Position the control box into the desired place and mark the mounting holes Select the mounting holes and remove the knockouts using a screwdriver and hammer Secure the control box to mounting surface 1 2 3 4 5 Depth 6 5 15 5 14 5 Mounting Surface Control Box Sealed Washer Mounting Fastener not supplied not supplied Installation Electronic Cont...

Page 22: ...e ground wire too short break it or destroy its integrity replace it with a single wire length Prevent unnecessary turns or loops in ground wires The gate operator and the battery charger require a single phase AC line to operate 1 Turn off the breaker for the circuit you are using 2 Select the proper voltage on the power board 3 Connect the incoming power wires to the proper terminals 4 Turn on t...

Page 23: ...the secondary unit with the primary unit Simply connect the Secondary arm to its applicable position IN for open inside or OUT for open outside Inside Outside Primary Unit Secondary Unit White Sm Green Sm Red Lg Black Lg Red Sm White Sm Green Sm Red Lg Black Lg Red Sm M M G OL B B CL www BrushlessGateOpeners com 800 878 7829 Sales BrushlessGateOpeners com ...

Page 24: ...fety Twist Wire Outside the Loop 6 Twists Foot Until Its Connection to the Loop Rack Inside Safety Loop Center Loop Outside Safety Loop Exit Loop Loop Connector Control Board Connector Loop Rack GOC LDR Safety Exit Center 28V Gnd Gnd Gnd www BrushlessGateOpeners com 800 878 7829 Sales BrushlessGateOpeners com ...

Page 25: ...WER FAIL The Auto Open feature in Platinum Access Systems Gate Operators enables the following functionality in the event of power failure a Open the gate in case of power failure 120 or 220 VAC b Keep the gate at the open position as long as the there is no power c Resume to normal operation when the power has been restored All accessories and safety devices are functional The only function disab...

Page 26: ...Sensor needs to be adjusted to compensate for the installation and gate weight The overload adjustment is provided to set the gate sensitivity a If the gate reverses by itself or stops in midcycle it is too sensitive b If the gate hits an object and does not reverse or stop it is not sensitive enough c Clockwise increases sensitivity counterclockwise decreases sensitivity Test and adjust for prope...

Page 27: ...e open manually FAIL SAFE SECURE SOLAR INSTALLATION Fail Safety Battery Detection AC Detection Output ON Normal Normal Secure ON Normal OFF Fail Safe ON Low OFF Normal Fail Safe ON Low OFF OFF Fail Safe OFF Normal Normal Secure OFF Normal OFF Fail Secure OFF Low OFF Normal Fail Secure OFF Low OFF OFF Fail Secure Connect To Solar Regulator Input 24 VDC Panel 12 VDC Panels From Solar Panel GOC REG24...

Page 28: ...ceptacle Earth Ground Green Yellow Neutral White Hot Black Green Reset Switch Solar Regulator Out White White Red Red Red Black Green Black Red White Installation Selectable Features www BrushlessGateOpeners com 800 878 7829 Sales BrushlessGateOpeners com ...

Page 29: ...ices REOPEN PHOTO BEAM Note Installing the photo beam in this way allows the gate to re open all the way upon obstruction of the photo beam The optional PBD connector provides a controlled power supply for Photo Beam The power will be turned off when gate is in close position to save battery ACCESSORY CONNECTIONS Open Commands Keypad Fire Override Safety Connections Edge Sensor Photo Beam TX Exit ...

Page 30: ...ving the radio receiver connected as illustrated and with the Timer OFF Every command of the radio transmitter will control the gate as follow A First command opens the gate B Second command CLOSE the gate if at open position C Third command OPEN the gate D Any subsequent commands will continue in the same order to control the gate This type of configuration is not recommended for a commercial ins...

Page 31: ...round The control switch box should be within sight of the gate out of reach of children and away from moving parts of the gate If no guard station or STOP switch is installed a jumper must be inserted between STOP NC and GND pins OPEN STOP GND STOP OPEN CLOSE CLOSE Solenoid Connection The solenoid power connection must be provided an external power source This will prevent damage to the battery i...

Page 32: ...gnetic Lock power connection must be provided an external power source This will prevent damaging the battery in the event of line power failure Green Black White Red Supplied with Lock Kit 24VDC Magnetic Lock Z Bracket PA MAG13 Supplied with Lock Kit www BrushlessGateOpeners com 800 878 7829 Sales BrushlessGateOpeners com ...

Page 33: ...hat the stop command is not active Check that the vehicular loop detectors are working properly Note Hold open timer closes the gate automatically once the gate reaches the limit open The time delay to close is set by the trim pot To turn this system off turn the trim pot all the way clockwise Check that all motor cable connections junctions and extensions are properly connected and color coded No...