7. OPERATION OF DISPLAY
The control unit has a handy display for viewing and programming the operating parameters. Furthermore, it constantly
shows gate status during normal operation.
When parameters are being displayed and adjusted, the display shows the selected parameter
on the left, and the relevant value on the right. Fig. 01 shows a display example of parameter
“
A
” at value “
2
”.
During normal operation, the display shows gate status. The displayed values are indicated on
the following table:
DISPLAY VALUE
GATE STATUS
- -
Gate at rest
O P
Gate opening
t c
Gate open in pause status (Only with automatic re-closure enabled - see next paragraph).
C L
Gate closing
During programming, the display shows value “
Pr
” for the whole time.
8. ADJUSTING THE OPERATING PARAMETERS
When you have made all the necessary connections, power up the system and check if all the signalling LEDs are in
the condition specified in paragraph 6.
To access parameter adjustment, follow the instructions below:
• Display shows value “
--
”.
• Press and hold down key
P2
until the display shows the name of the first parameter.
• Press push-button P1 to change the value of the parameter.
• To move on to the next parameter, press push-button
P2
again..
• When 60 seconds have elapsed without any key being touched, the control unit exits the adjustment mode. You
can manually exit the adjustment mode by scrolling all the parameters. When the displays show “
--
” , you have
returned to normal operation.
The following table summarises the different parameters and the assignable values.
DISPLAY
DISPLAY
Sensitivity adjustment of electronic clutch and motor force.
A1
Minimum motor force, more sensitive to obstacle.
A2
Medium-low motor force, low sensitivity to obstacle.
A3
Medium-high motor force, high sensitivity to obstacle.
A4
High motor force, high sensitivity to obstacle.
Automatic re-closure:
this function enables or disables automatic gate closing.
c0
Disabled
c1
Enabled
Operation of OPEN A
command: this function determines the behaviour of the OPEN A (total opening) push-button.
d0
Opens / Closes / Opens
d1
Opens / Stops/ Closes / Stops
Reversing stroke after closing:
if this function is enabled, the gate will effect about half its opening stroke, after closing.
This allows to relieve the release device, facilitating its possible operation.
E0
Disabled
E1
Enabled
Condo function:
if this function is enabled while the gate is being opened, the start command is inhibited.
F0
Disabled
F1
Enabled
Deceleration point percentage:
this parameter is used to set the length of the decelerated section, selecting it from
the two set values.
H0
20% of maximum memory-stored opening
Fig. 01
Summary of Contents for 724 D-24V
Page 9: ...ITALIANO 12 SCHEMA DI COLLEGAMENTO...
Page 19: ...17 ENGLISH 12 CONNECTION LAY OUT...
Page 29: ...27 FRAN AIS 12 SCH MA DE CONNEXION...
Page 39: ...37 ESPA OL 12 ESQUEMA DE CONEXI N...
Page 49: ...47 DEUTSCH 12 ANSCHLUSSPLAN...
Page 59: ...57 NEDERLANDS 12 AANSLUITSCHEMA...
Page 69: ...57 NEDERLANDS 12 AANSLUITSCHEMA...
Page 73: ...note notes note notas anmerkung opmerkingen...