6. TIME LEARNING
Time learning instructions:
1. Release the automated system and put it into closed position.
Check if the closing travel-limit sensor (if present) is engaged
(FCC LED OFF) and if the STOP and SAFE LEDs are lighted;
2. press SW1 and hold it down until the automated system begins
the opening operation;
3. Operation without travel-limit sensor: when the automated system
has reached opening position, wait 2-3 seconds and then press
SW1 again or command OPEN to stop the operator;
Operation with travel-limit sensor:the automated system will stop
automatically when the opening limit-switch is reached. After
the motor stops, the board begins to learn the extra work time
(time-out after which the board commands the motor to stop if
the stop limit-switch is not reached correctly). Wait for the time
you require (max= 10 min), and then press OPEN or SW1 to save
it;
4. if the A or AP logic is set, after completing the procedure at point
3, the board starts to learn the pause time. Wait for the pause time
you require, and then press OPEN or SW1 again to save it (max
= 5 min) and the automated system will automatically begin to
close the door;
5. if, instead, a logic other than A or AP is set, the learning stops at
point 3. To close the door, press OPEN or CLOSE, according to
the logic.
7. AUTOMATED SYSTEM TEST
When you have finished programming, check if the system is
operating correctly. In particular, check if the safety devices are
operating correctly.
8. FUNCTION LOGICS
5. PROGRAMMING THE FUNCTION LOGIC
To select the function logic, press the SW1 push-button the number
of times equal to the number of the required logic, irrespective of the
current logic and the door status. The interval between the pulses
must be less than 1 second.
The selected logic is then continuously displayed by the DL1 LED,
which flashes once a second at 3 sec intervals, equal to the number
of the required logic.
To select the logics, press SW1 the number of times indicated in the
table below:
No.
Logic
Description
SW1 PRESSINGS
1
B/C
mixed B / C
once
2
B
Semiautomatic B
twice
3
C
manned
3 times
4
EP
(default)
Stepped semiautomatic
4 times
5
AP
Stepped automatic
5 times
6
P
Stepped automatic
6 times
7
A
Automatic
7 times
6.1.
LEDS CHECK
6. START-UP
The following table shows the status of the LEDs in relation to the
status of the inputs (the closed at rest automated system condition
is shown in bold). If the travel-limit sensor inputs are connected to
terminal 7 (-), the FCA and FCC LEDs are always lighted. Check the
status of the signalling LEDs as per table below:
Operation of status signalling LEDs
LED
ON (closed contact)
OFF (Open contact)
DL1
Flashing to indicate selected logic
OP-A
Command enabled
Command disabled
CLOSE
Command enabled
Command disabled
SAFE
Safety devices disabled
Safety devices engaged
STOP
Command disabled
Command enabled
FCA
Opening limit switch free
Opening limit switch
engaged
FCC
Closure limit switch free
Closing limit switch
engaged
Logic B/C
Status
Open
(pulse)
Close
(maintained)
Stop
Safe
Closed
Opens
/
Disables
Open and Close
/
Opening
/
Closes
Locks
/
Open
/
Closes
Disables
Open and Close
Disables
closing
Closing
Opens
Closes
Locks
Opens
Locked
Opens
Closes
Disables
Open and Close
Disables
closing
Logic B
Status
Open
(pulse)
Close
(pulse)
Stop
Safe
Closed
Opens
/
Disables
Open and Close
/
Opening
/
Closes
Locks
/
Open
/
Closes
Disables
Open and Close
Disables
closing
Closing
Opens
/
Locks
Opens
Locked
Opens
Closes
Disables
Open and Close
Disables
closing
Logic C
Status
Open
(held)
Close
(held)
Stop
Safe
Closed
Opens
/
Disables
Open and Close
/
Opening
Opens
Locks
Locks
/
Open
/
Closes
Disables
Open and Close
Disables
closing
Closing
Opens
Closes
Locks
Locks
Locked
Opens
Closes
Disables
Open and Close
Disables
closing
Logic EP
Status
Open
(pulse)
Close
(pulse)
Stop
Safe
Closed
Opens
/
Disables
Open and Close
/
Opening
Locks
Closes
Locks
/
Open
Closes
Closes
Disables
Open and Close
Disables
closing
Closing
Locks
/
Locks
Opens
Locked
Starts in opposite
direction (always
closes after a Stop)
Closes
Disables
Open and Close
Disables
closing
Logic AP
Status
Open
(pulse)
Close
(pulse)
Stop
Safe
Closed
Opens and closes
after pause time
/
Disables
Open and Close
/
Opening
Locks
Closes
Locks
/
Pause
Locks
Closes
Locks
Repeats
pause
Closing
Opens
/
Locks
Opens
Locked
Closes
Closes
Disables
Open and Close
Disables
closing
Logic P
Status
Open
(pulse)
Close
(pulse)
Stop
Safe
Closed Opens
/
Disables
Open and Close
/
Opening
/
Completes opening
and then closes
Locks
/
Open
/
Closes
Disables
Open and Close
Disables
closing
Closing Opens
/
Locks
Locks and clo-
ses on release
Locked Opens
Closes
Disables
Open and Close
Disables
closing
Status
Open
(pulse)
Close
(pulse)
Stop
Safe
Closed Opens and closes
after pause time
/
Disables
Open and Close
/
Opening
/
Completes
opening and
then closes
Locks
/
Pause
Recharges
pause time
Closes
Locks
Recharges
pause time
Closing
Opens
/
Locks
Opens
Locked
Opens
Closes
Disables Open
and Close
Disables
Close
Logic A