WHAT TO DO IF....
Symptom
Cause
Remedy
The awning closes even
without any wind
blowing.
Low batteries.
Open the sensor shell and
deactivate it: if the LED fl ashes, the
batteries are almost drained. If the
LED is OFF and it does not come
back on, the batteries are dead.
Change the batteries.
Problems with radio
communications.
Check that the sensor is not too
far from the motor or the radio
receiver. Change the position of
the sensor.
Sensor deactivated.
The sensor is not active. Perform
the activation procedure again.
The awning motor
does not make its
activation confi rmation
movements, when the
shell is snapped onto
the base.
The sensor was not
able to detect a
stable position.
Check the sensor attachment.
Check that the terminal bar is not
vibrating.
The sensor detected
a stable position
before being
snapped into place.
Repeat the activation procedure,
taking care to attach the sensor
within ten seconds of the
confi rmation fl ash.