![FAAC 145503 Manual Download Page 21](http://html.mh-extra.com/html/faac/145503/145503_manual_535245021.webp)
TM2
X
W
21
A4518_6H02_Rev.A
SETTING THE SENSOR
Tn
Tn
2 sec
set
Tn: already programmed remote control
To associate the sensor to a motor, a remote control must be already memorised
on the motor. The setting sequence is the following:
At this point, do not assemble the sensor shell on the base.
Note: to check proper memorisation, press the SET button briefly again: the awning
should move about half way through its path. When the check is completed, open
the awning once again.
1
9
2
3
4
5
8
7 6
0
• Press the buttons on the remote control in this sequence: A+B and B, and then
the SET button for 2 seconds on the TM2 X W sensor; until the motor performs
the confirmation movement (around 2 second).
The vibration detection threshold is set by choosing one of the positions on the ro-
tating selector, from 1 (light vibrations) to 9 (strong vibrations). The proper threshold
setting for each type of awning must be determined, through trial and error. Start
out by setting a middle value (e.g. 5) and then activate the sensor. After activation
it will be possible to perform tests to find the best threshold.
VIBRATION THRESHOLD
• Insert the batteries provided;
• Open the awning completely (button C);
• Rotate the selector to the 0 position;
set
+
A
B
B
C
EN
Summary of Contents for 145503