DELETING THE SENSOR
To delete the TM2 X W sensor from the motor, an already programmed remote
control must be used. The deleting sequence is the following:
Tn
Tn
2 sec
set
Following a wind alarm, the motor closes automatically the awning, overriding
user commands until the wind alarm passes. To deactivate the wind alarm, the
vibrations caused by the wind must remain below the threshold set for at least 8
minutes. After these 8 minutes the awning returns to the position it was in before
the alarm, if the automatic reopening function is active. This pause time is included
to ensure awning protection and to prevent continuous motor movement in the
event of sporadic gusts of wind.
ACTIVATING AUTOMATIC REOPENING
Tn
Tn
Tn (2 sec)
With the automatic reopening system, at the end of the wind alarm, the awning
opens again. From factory this function is not activated in the motor, but can be
easily activated with the following command sequence:
Tn: Already programmed remote control
AUTOMATIC REOPENING
- only with TM2 ERY -
Tn
Tn
Tn (2 sec)
DEACTIVATING AUTOMATIC REOPENING
The automatic reopening function can be deactivated at any moment with the
following command sequence:
+