TM2
X
W
19
A4518_6H02_Rev.A
FUNCTION OPEN/CLOSE PROGRAMMING REMOTE
CONTROL TM 2 X T
To prevent accidental changes to the programming of the motor during the daily
use of the remote control, the possibility of programming is disabled automatically
8 hours after sending the last sequence (A+B or B+C).
CHECKING THE STATUS OF THE FUNCTION
To change the status of the function, see the sequences “enable/disable pro-
gramming”
Proceed with programming as the instructions booklet
ENABLE PROGRAMMING
Disable programming
ON
Open
programming
Closed
programming
....
ON
....
....
Closed
Open
ON
or after
30 sec.
or after
30 sec.
1
Tn
2
3
OPTION 1
1
Tn
2
3
1
Tn
2
3
or after
30 sec.
OPTION 2
OPTION 2
+
+
A
B
C
B
B
C
+
+
A
B
C
+
+
A
B
C
A
B
OPTION 2
OPTION 2
Remove a battery
and wait 5 secon-
ds, or press any
button.
2 sec
B
EN