6.
FINAL PLATFORM/RAMP STEPS AND CHECKS
6.1.
ATTACH FRAME POSTS TO PLATFORM POSTS
6.1.1.
At all locations where a frame post is not connected to a rail, picketed guard, or
closure component it must be connected to a platform angle post using a ramp
closure bracket (FIG. 6.1).
The ramp closure bracket is the smaller of the two closure brackets with 1-3/4”
and 3-3/4” long legs and is only used on the outside where a ramp meets a
platform.
6.1.2.
If installing the ramp closure bracket on a ramp with a two-line rail, first remove the
5/16”-18 x 2-1/4” long hex bolt and 5/16” flat washer from the mid rail then
reinstall through the short leg of the bracket, the frame post and back into the
threaded insert. Orient the bracket as shown (FIG. 6.1) with the long leg contacting
the platform angle post.
6.1.3.
If installing the ramp closure bracket on a ramp with a picketed guard, install a
5/16”-18 x 2-1/4” long hex bolt through a 5/16” flat washer, the short leg of the
bracket and the hole approximately in the middle of the frame post then secure
with another 5/16” flat washer and a 5/16”-18 nylon insert locknut. Orient the
bracket as shown (FIG. 6.1) with the long leg contacting the platform angle post.
6.1.4.
Attach the long leg of closure bracket to the platform angle post using a 5/16”-18 x
1” long hex bolt, 5/16” flat washers, and a 5/16”-18 nylon insert locknut oriented as
shown (FIG. 6.1). Use an existing hole in the platform angle post if possible or field-
drill a new 11/32” or 3/8” hole.
6.1.5.
Tighten all fasteners securely.
FIG. 6.1