MTPX Plus Series Setup Guide • Remote Control and Optimizing the Video
25
If you selected a serial port in step 2
, the Matrix Switcher Control Program is ready
for operation.
If you selected IP [LAN] in step 2
, the IP Connection window appears.
a.
Examine the
Matrix IP Address
text box, which displays the last Matrix IP
address entered.
If necessary
, enter the correct IP address in the text box.
NOTE:
192.168.254.254 is the factory-specified default value for this field.
b.
If the switcher is password protected, enter the administrator or user password in
the
Password
text box.
NOTE:
The factory configured passwords for all accounts on this device have
been set to the device serial number. Passwords are case sensitive.
If the device is reset, the password will be the original password configuration,
which is no password.
d.
Click
Connect
.
The Matrix Switchers Control Program is ready for operation.
Optimizing the video
Each TP input has a level and peaking adjustment. Most MTP transmitters and half of
the MTPX Plus TP outputs have a pre-peaking feature. TP inputs and outputs have skew
adjustments. See the following sections to set these adjustable features.
NOTE:
Unless the TP cables are changed, these adjustments should need to be made
only once, during installation.
Before you start optimizing
, set all input level and peaking, input and output skew, and
ouput
Pre-Peak
settings to either zero or off.
Setting the MTP transmitter Pre-Peak feature
For inputs from MTP T 15HD products
only
—
If the cable between the MTP transmitter
and the MTPX Plus is 300 feet (91 m) or longer, turn on the
Pre-Peak
switch on the
transmitter. For shorter cables, turn the switch off.
Setting MTPX level and peaking using the MTP signal generator
The simplest and surest way to set the input level and peaking is to use the included MTP
signal generator and the Auto-calibration utility within the Matrix Switchers Control Program
as follows:
NOTE:
To manually set the input level and peaking, see
1.
Disconnect the power and RJ-45 cables at the MTP transmitter that is connected to
the MTPX Plus input to be adjusted.
2.
Connect the two cables to the included MTP signal generator.
Summary of Contents for MTPX 3232