MKP 2000 • Installation
5
11.
Use the control panel to select
page 17).
The MKP 2000 remote control panel should be installed in a standard, 2-gang electrical wall
box (see figure 3). In figure 3, the MKP is installed in a wall. It could also be installed in a
desk, a podium, or any other convenient location.
The procedures provided here assume that the electrical wall boxes and the cables have
been installed for the system (see
Rear Panel and Side Panel Connections
page 9 to terminate the cables).
Installation
The MKP 2000 remote control panel should be installed in a standard, 2-gang electrical wall
box (see figure 3). The diagram shows the MKP installed in a wall. It could also be installed
in a desk, a podium, or any other convenient location.
The procedures provided here assume that the electrical wall boxes and the cables have
been installed for the system (see
Rear Panel and Side Panel Connections
to terminate
the cables).
MK
P 2
000
4
5
6
1
2
3
7
8
9
BA
CK
0
CAN
CEL
INPUT
OUTPUT
TAK
E
R
Figure 3.
MKP Mounted in a Wall Box
UL Requirements for Wall Box Installation
The following Underwriters Laboratories (UL) requirements pertain to the installation of the
MKP 2000 into a wall or furniture (see figure 3).
1.
These units are not to be connected to a centralized DC power source or used beyond
their rated voltage range.
2.
These units must be installed in UL listed junction boxes.
3.
These units must be installed with conduit in accordance with the National Electrical
Code.
figure 3