MGP Pro Series • Remote Configuration and Control
55
Command
ASCII (Telnet)
(Host to Processor)
Response
(Processor to Host)
Additional Description
Output Scaler Resolution and Rate (continued)
View output rate details
0 =
width
*
height
*
refresh
rate
]
View the current output resolution
and refresh rate in actual numbers.
NOTE:
The View output rate details command can display the actual resolution of the output when the MGP Pro is configured to use the live
background rate.
Example:
0 =
1024*0768*060
]
The output resolution is 1024x768.
The rate is 60 Hz.
Freeze
Enable freeze
X@
* 1 F
X@
Frz 1
]
Freeze the output video image in
window
X@
.
Disable freeze
X@
* 0 F
X@
Frz 0
]
Unfreeze the output image
View freeze status
X@
F
X$
]
View freeze status
X$
. F
KEY:
X@
= Window number
0 = All windows (available only for
1 = Window 1
3 = Window 3
freeze and window mute)
2 = Window 2
4 = Window 4
X$
= Pixel phase
0 - 31
Test Pattern
Set test pattern
X%
J
Tst
X%
]
Select test pattern
X%
.
View test pattern
J
X%
]
View the currently selected test
pattern.
KEY:
X%
= Test pattern
0 = Off (none)
5 = Ramp
10 = Quad Split (4 x 4)
1 = Colorbars
6 = Alt. Pixels
11 = PIP Images (4 x 3 or 6 x 9 PIP columns)
2 = X-Hatch (16 x 12)
7 = White Field
12 = 1.78 Aspect (4 x 3/16 x 9)
3 = 4 x 4 X-Hatch
8 = Crop
13 = 1.85 Aspect (4 x 3/16 x 9)
4 = Grayscale
9 = Side-By-Side (4 x 3 crop)
14 = 2.35 Aspect (4 x 3/16 x 9)
Executive Mode
NOTE:
In all front panel lock modes, RS-232, RS-422, and Ethernet controls are not affected.
Disable executive mode
0 X
Exe 0
]
Unlock all front panel controls.
Enable executive mode
1 X
Exe 1
]
Lock front panel controls except for
the input buttons.
Enable executive mode 2
2 X
Exe 2
]
Lock all front panel controls.
View executive mode status
X
X3%
]
View executive mode status
X3%
.
KEY:
X3%
= Front panel lock
(executive mode) status
0 = Unlocked
1 = Locked except for input selection buttons
2 = All controls are locked
NOTE:
Front panel lockout does not include RS-232, RS-422, and Ethernet control.
Special Functions
Output polarity
Example:
1 *
X3^
#
1 * 2 #
Pol
X3^
]
Pol 2
]
Set output polarity to
X3^
.
View output polarity
1 #
X3^
]
View the current output polarity
setting
X3^
.
KEY:
X3^
= Output polarity
0 = H-/V- (default)
1 = H-/V+
2
=
H+/V-
3
=
H+/V+