IN1606 and IN1608 Series Scaling Presentation Switcher • Reference Information
87
UL Guidelines for rack mounted devices
The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the
scaler in a rack.
1.
Elevated operating ambient temperature
— If installed in a closed or multi-unit
rack assembly, the operating ambient temperature of the rack environment may be
greater than room ambient temperature, Therefore, install the scaler in an environment
compatible with the maximum ambient temperature (Tma = +122 ˚F, +50 ˚C) specified
by Extron.
2.
Reduced air flow
— Install the equipment in a rack so that the amount of air flow
required for safe operation of the equipment is no compromised.
3.
Mechanical loading
— Mount the equipment in the rack so that a hazardous
condition is not achieved due to uneven mechanical loading.
4.
Circuit overloading
— Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when
addressing this concern.
5.
Reliable earthing (grounding)
— Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections
to the branch circuit (e.g. use of power strips).
Furniture Mounting
See the Extron website,
www.extron.com
, for a list of available furniture mounting kits. To
install the scaler to furniture, follow the mounting kit instructions.
#8 Screw
(4) Places
Each Side
MBU 149
Mounting Bracket
Mounting Screws
(2) Places
Each Side
Figure 65.
Under-Desk Mounting