IN1606 and IN1608 Series Scaling Presentation Switcher • SIS Communication and Control
37
Command
ASCII Command
(host to scaler)
Response
(scaler to host)
Additional Description
Auto-Image
Enable
X!
*1A
Img
X!
*1
]
Activate Auto-Image for input
X!
.
Disable
X!
*0A
Img
X!
*0
]
Turn off Auto-Image for input
X!
.
View
X!
A
X(]
View the Auto-Image setting for
input
X!
.
Execute
A
Img0
]
Execute an Auto-Image for the
current input (follows the aspect
ratio of the current input).
Execute and fill
1*A
Img1
]
Execute an Auto-Image and fill the
entire output.
Execute and follow
2*A
Img2
]
Execute an Auto-Image and
maintain the aspect ratio of the
current input.
Auto-Image threshold value (luminosity value which the scaler defines as active video for Auto-Image)
Set value
EX2(
ALVL
}
Alvl
X2(]
Set the global Auto-Image
luminosity to
X2(
.
View
E
ALVL
}
X2(]
View the global Auto-Image
luminosity setting.
Horizontal start
Specify a value
EX$
HSRT
}
Hsrt
X!
*
X$]
Set the horizontal start position.
Increment value
E
+HSRT
}
Hsrt
X!
*
X$]
Increase the horizontal start
position.
Decrement value
E
-HSRT
}
Hsrt
X!
*
X$]
Decrease the horizontal start
position.
View
E
HSRT
}
X$]
View the horizontal start position.
Vertical start
Specify a value
EX$
VSRT
}
Vsrt
X!
*
X$]
Set the vertical start position.
Increment value
E
+VSRT
}
Vsrt
X!
*
X$]
Increase the vertical start position.
Decrement value
E
-VSRT
}
Vsrt
X!
*
X$]
Decrease the vertical start
position.
View
E
VSRT
}
X$]
View the vertical start position.
NOTES:
X!
= Input selection
1-6
(IN1606) or
1-8
(IN1608 models)
X$
= H/V start
0-255
X(
= Enable or disable
0
= off or disabled
1
= on or enabled
X2(
= Auto-Image threshold value
0-100
(where
0
= black and
100
= white;
25
= default)