IN1606 and IN1608 Series Scaling Presentation Switcher • Operation
15
Powering Up
When power is applied to the scaler, the Input selection buttons light amber, green, and then
red before illuminating just the selected input.
Input Selection
Press any of the Input selection buttons on the front panel to select an input. The current
active input lights as follows:
Input Selection Button Lights
Color
Signal
Amber
Audio and video
Green
Video only
Red
Audio only
On-Screen Display (OSD) Menu System
Scaler configuration and adjustments can be performed by using the internal Web
pages (see
Internal Web Pages
on page 56), the Product Configuration Software (see
Configuration Software
on page 50), the Extron Simple Instruction Set (SIS) of commands
(see
SIS Configuration and Control
on page 29), or by using the front panel controls and
the OSD menu. The OSD menu is used primarily when the scaler is first set up.
NOTE:
The OSD menu has a fixed time-out of 60 seconds.
Menu Navigation Using Front Panel Controls
Menu button
— Press the Menu button to activate the OSD menu or close submenus and
settings.
Enter button
— Press the Enter button to activate the OSD menu or select submenu
items.
Navigation buttons
— Press the Up (
>
) button or the Down (
<
) button to navigate
submenus or submenu items. Press the Right (
>
) button to access currently selected
submenus or submenu items. Press the Left (
>
) button to exit currently selected submenus
or submenu items. Also use the navigation buttons to adjust settings according to specific
setting directions.
Input Selection buttons
— Press any of the Input selection buttons to change the
selected input.