36
DXP HD 4K Series • Remote Control
X1@
= Audio and video mute status
0
= All audio and video unmuted
1 = Video muted (one or more outputs)
2
= Audio muted (one or more outputs)
3 = Video and audio muted (one or
more outputs)
X1$
= Total inputs
Total number of inputs for this switcher
X1%
= Total outputs
Total number of outputs for this
switcher
X1^
= Voltage
Positive or negative voltage and
magnitude
X1&
= Temperature
Degrees Centigrade
X1*
= Fan speed
In RPM
X1(
= EDID reference file for DDC
9
= 720p @ 60 Hz (default)
data
beginning on
page 32.
DXP 44 and 84:
1
–
17
= fixed factory rates
18
–
21
= not selectable (outputs)
26
–
33
= user assignable
DXP 88:
1
–
17
= fixed factory rates
18
–
25
= not selectable (outputs)
26
–
33
= user assignable
DXP 168:
01 – 17 = fixed factory rates
18 – 25 = not selectable (outputs)
34 – 49 = user assignable
DXP 1616:
1
–
17
= fixed factory rates
18
–
33
= not selectable (outputs)
34
–
49
= user assignable
X2!
= Firmware version (
n
.
nn
)
Shown to second decimal place
X2%
= Front panel lock mode status
0
= lock mode 0
(executive mode)
1
= lock mode 1
2
= lock mode 2
X3^
= IP address or gateway address
nnn.nnn.nnn.nnn
X3&
= Subnet mask
nnn.nnn.nnn.nnn
X4^
= DHCP
0
= off,
1
= on
X5#
= Verbose mode
0
= clear/none (default for Telnet
connection)
1
= verbose mode (default for RS-232
and USB connections)
2
= tagged responses for queries
3
= verbose mode and tagged
NOTE:
If tagged responses is enabled (modes 2 and 3), all read commands
return the constant string and the value as the set command does (for
example, the read matrix name command
E
CN
}
, returns
Ipn
•
X3)
]
).