Model VX-RPS-CH3
The following table lists the specifications for the 3-slot modular shelf (model VX-RPS-CH3). The shelf is
designed for use with the following equipment:
•
VX-RPS-1000 Redundant Power Supply
Table 356: Physical Specifications
Length
44.0 cm (17.34 in.)
Depth
38.7 cm (15.25 in.)
Height
4.4 cm (1.73 in.)
Weight
2.89 kg (6.37 lb)
Power Cord Requirements for AC-Powered Switches and AC Power
Supplies
An AC power cord is not included with the AC power supply.
Power cords used with AC-powered switches or AC power supplies must meet the following
requirements:
•
The power cord must be agency-certified for the country of use.
•
The power cord must have an IEC320-C13 connector for connection to the switch or power supply.
•
The power cord must have an appropriately rated and approved wall plug applicable to the country
of installation.
•
For cords up to 6 feet (2 m) long, the wire size must be 18 AWG (.75 mm
2
) minimum; over 6 feet, the
minimum wire size is 16 AWG (1.0 mm
2
).
For details about obtaining AC power cords for use in your country, refer to
www.extremenetworks.com/product/powercords/
Console Connector Pinouts
describes the pinouts for a DB-9 console plug connector.
Table 357: Pinouts for the DB-9 Console Connector
Function
Pin Number
Direction
DCD (data carrier detect)
1
In
RXD (receive data)
2
In
TXD (transmit data)
3
Out
DTR (data terminal ready)
4
Out
GND (ground)
5
-
DSR (data set ready)
6
In
RTS (request to send)
7
Out
CTS (clear to send)
8
In
Technical Specifications
Model VX-RPS-CH3
ExtremeSwitching Hardware Installation Guide 475