Refer to the Security chapter in the
for information about configuring the
host switch to work with the LRM/MACsec Adapter.
Installing a Half-Duplex to Full-Duplex Converter
The following options are available for installing the Half-Duplex to Full-Duplex Converter:
1. On a shelf that is mounted in an equipment rack. (The shelf can accommodate up to three
converters.)
Installing Half-Duplex to Full-Duplex Converters in a 3-Slot Modular Shelf
2. On a flat surface.
Mounting a Half-Duplex to Full-Duplex Converter on a Flat Surface
3. On a wall.
Mounting a Half-Duplex to Full-Duplex Converter on a Wall
Installing Half-Duplex to Full-Duplex Converters in a 3-Slot Modular Shelf
Refer to
Installing a Half-Duplex to Full-Duplex Converter
on page 320 for installation options for the
Half-Duplex to Full-Duplex Converter.
Before installing the converter in the 3-slot modular shelf (part no. STK-RPS-1005CH3), mount the shelf
in the rack. Follow the steps in the
3-Slot Modular Shelf Quick Reference Guide
.
To install up to three Half-Duplex to Full-Duplex Converter units in the 3-slot modular shelf, follow these
steps:
1. Attach the four rubber feet (included) to the bottom of the converter, one at each corner.
2. Set the converter on the shelf.
3. Connect the converter to its power adapter, following the instructions in
to Full-Duplex Converter to its Power Adapter
4. Secure the converter to the shelf using cable ties (included with the shelf).
Pass the ties through the holes in the shelf and secure them firmly around the converter.
5. Connect the full-duplex ports (FD1 - FD4) to the switch.
6. Connect the half-duplex ports (HD1 - HD4) to your half-duplex devices.
7. Install one or two additional Half-Duplex to Full-Duplex Converter units in the shelf, as described in
steps
.
Mounting a Half-Duplex to Full-Duplex Converter on a Flat Surface
Refer to
Installing a Half-Duplex to Full-Duplex Converter
on page 320 for installation options for the
Half-Duplex to Full-Duplex Converter.
To install a Half-Duplex to Full-Duplex Converter unit on a flat surface, follow these steps:
1. Attach the four rubber feet (included) to the bottom of the converter, one at each corner.
2. Set the converter on a flat, stable surface.
Installing a Half-Duplex to Full-Duplex Converter
Installing Expansion Modules
320 ExtremeSwitching Hardware Installation Guide