AC Power Cable Requirements
Use an AC power cable appropriate for your country. Check your local electrical codes and regulatory
agencies for power cable requirements. The countries listed in
Table 15
have additional requirements as
listed in the table.
NOTE
When using dual power supplies, make sure that each AC power supply attaches to an independent power source.
Replacing the AC Power Cable
If the power cable plug is unsuitable and must be replaced, connect the power supply wires for the
switch according to the following scheme:
●
Brown wire to the Live (Line) plug terminal, which may be marked with the letter “L” or colored
red.
●
Blue wire to the Neutral plug terminal, which may be marked with the letter “N” or colored black.
●
Yellow/Green wire to the Ground plug terminal, which may be marked with the letter “E” (the
Earth symbol) or colored yellow/green.
Uninterruptible Power Supply Requirements
An uninterruptible power supply (UPS) is a device that sits between a power supply (such as a wall
outlet) and a device (such as a switch) to prevent outages, sags, surges, and bad harmonics from
adversely affecting the performance of the device.
A UPS traditionally can perform the following functions:
●
Absorb relatively small power surges.
●
Smooth out noisy power sources.
●
Continue to provide power to equipment during line sags.
●
Provide power for a period of time after a blackout has occurred.
Table 15: AC Power Cable Requirements
Country
Requirements
USA and Canada
• The cable set must be UL-approved and CSA-certified.
• The minimum specification for the flexible cable is No. 18
AWG (1.5 mm
2
), Type SVT or SJT, 3-conductor.
• The cable set must have a rated current capacity of at least the amount rated for each
specific product.
• The attachment plug must be either an Earth-grounding type with a NEMA 5-15P (10
A, 110 V) configuration or a NEMA L6-15P (10 A, 208/240 V)
Denmark
The supply plug must comply with section 107-2-D1, standard DK2-1a or DK2-5a.
Switzerland
The supply plug must comply with SEV/ASE 1011.
Argentina
The supply plug must comply with Argentinian standards.
Summary of Contents for BlackDiamond 12800 Series
Page 8: ...Table of Contents BlackDiamond 12800 Series Switches Hardware Installation Guide 8...
Page 12: ...Preface BlackDiamond 12800 Series Switches Hardware Installation Guide 12...
Page 13: ...1 BlackDiamond 12800 Series Switches...
Page 14: ......
Page 39: ...2 Installing BlackDiamond Switches and Modules...
Page 40: ......
Page 113: ...3 BlackDiamond Maintenance Procedures...
Page 114: ......
Page 131: ...4 Appendixes...
Page 132: ......
Page 146: ...Safety Information BlackDiamond 12800 Series Switches Hardware Installation Guide 146...
Page 160: ...Index BlackDiamond 12800 Series Switches Hardware Installation Guide 160...