Meeting Site Requirements
BlackDiamond 12800 Series Switches Hardware Installation Guide
45
Figure 20: Airflow Through the BlackDiamond 12804 Chassis
Electrostatic Discharge
Your system must be protected from static electricity or electrostatic discharge (ESD). Take the following
measures to ensure optimum system performance:
●
Remove materials that can cause electrostatic generation (such as synthetic resins) from the wiring
closet. Check the appropriateness of floor mats and flooring.
●
Connect metal chassis, conduit, and other metals to ground using dedicated grounding lines.
●
Use electrostatically safe equipment and the ESD-preventive wrist strap that is provided with your
equipment. All switches come with ESD-preventive wrist strap connectors and an ESD-preventive
wrist strap as shown in
Figure 21
.
Figure 21: Using an ESD-Preventive Wrist Strap
AS
P051
A
ir
f
low at power
supply level
A
ir
f
low through
f
an tray
BD_171
ESD
strap
ESD wrist strap
connector
Summary of Contents for BlackDiamond 12800 Series
Page 8: ...Table of Contents BlackDiamond 12800 Series Switches Hardware Installation Guide 8...
Page 12: ...Preface BlackDiamond 12800 Series Switches Hardware Installation Guide 12...
Page 13: ...1 BlackDiamond 12800 Series Switches...
Page 14: ......
Page 39: ...2 Installing BlackDiamond Switches and Modules...
Page 40: ......
Page 113: ...3 BlackDiamond Maintenance Procedures...
Page 114: ......
Page 131: ...4 Appendixes...
Page 132: ......
Page 146: ...Safety Information BlackDiamond 12800 Series Switches Hardware Installation Guide 146...
Page 160: ...Index BlackDiamond 12800 Series Switches Hardware Installation Guide 160...