Power Supplies for the BlackDiamond 12800 Series Switches
BlackDiamond 12800 Series Switches Hardware Installation Guide
151
Power Supplies for the BlackDiamond 12800 Series
Switches
This section lists specifications for the power supplies that are installed in the following BlackDiamond
switches:
●
BlackDiamond 12804 switch
●
BlackDiamond 12802 switch
Operating conditions
Operating temperature range 0° C to 40° C (32° F to 104° F)
Operating humidity:10% to 93% relative humidity, non-condensing
Operating altitude 0 to 3000 meters (0 to 9,850 ft)
Operational shock: 30 m/s
2
(3 g), 11 ms, 60 shocks
Operational random vibration: 5 to 500 Hz @ 1.5g rms
Storage & transportation
conditions (packaged)
Transportation temperature: –40° C to 70° C (–40° F to 158° F)
Storage and transportation humidity: 10% to 93% relative humidity,
non-condensing
Packaged shock (half sine):
<50 kg 180 m/s
2
(10 g), 6 ms, 600 shocks, modules
>50 kg 100 m/s
2
(6 g), 11 ms, 600 shocks, chassis
Packaged random vibration: 5 to 20 Hz @ 1.0 ASD w/–3dB/oct. from 20 to
200 Hz
Packaged sinusoidal vibration: 5 to 62 Hz, 5 mm/s velocity, 62 to 200 Hz,
0.2 G
Tilt: 22.5 degrees and return to position
14 drops minimum on sides & corners
@ 39.4" <20 lb (9 kg) modules
@ 19.7" <80 lb (36 kg) chassis
Table 26: AC SSI PS Model #60020/PS2336 (700/1200 W AC PSU)
For the BlackDiamond 12804 switch
Typical configuration
3 power supplies
Full configuration
6 power supplies
Input
Nominal input: 100 to 240 V
, 60/50 Hz, 10 A max
AC voltage input range: 90 to 264 V
Maximum input amperages:
7 A @ 200 V
(high-line)
10 A @ 90 V
(low-line)
AC line frequency: 47 to 63 Hz
PS input socket: IEC 320 C14
Minimum wire size: 16 AWG (1.31mm
2
) copper stranded
Output
DC output: 48 V
, 24 A/12 V
, 4 A (high-line)
48 V
, 13.5 A/12 V
, 4 A (low-line)
DC output power (W): 700 to 1200 W
Power supply cord selection
Refer to
“Selecting Power Supply Cords” on page 136
.
AC power supply input socket
IEC 320 C14
Minimum wire size
16 AWG (1.0mm
2
) copper stranded
(pre-approved cord set for county of use)
Operating conditions
Operating temperature: 0° C to 40° C
Storage temperature: –40° C to 70° C
Operating humidity: 10% to 90% relative humidity, non-condensing
Operational shock: 30 m/s
2
(3 g)
Table 25: BlackDiamond 12802 Switch Technical Specifications (Continued)
Summary of Contents for BlackDiamond 12800 Series
Page 8: ...Table of Contents BlackDiamond 12800 Series Switches Hardware Installation Guide 8...
Page 12: ...Preface BlackDiamond 12800 Series Switches Hardware Installation Guide 12...
Page 13: ...1 BlackDiamond 12800 Series Switches...
Page 14: ......
Page 39: ...2 Installing BlackDiamond Switches and Modules...
Page 40: ......
Page 113: ...3 BlackDiamond Maintenance Procedures...
Page 114: ......
Page 131: ...4 Appendixes...
Page 132: ......
Page 146: ...Safety Information BlackDiamond 12800 Series Switches Hardware Installation Guide 146...
Page 160: ...Index BlackDiamond 12800 Series Switches Hardware Installation Guide 160...