32
Chapter 8
Parameter A (D2=A(fl ashing); D1=Ex. “OFF 1”)
At this point the values introduced in this parameter have no value as the ignition and switch-off of the 3rd
time span have been disabled.
To confi rm and continue programming, press button 5.
Press button 4 to go back to the previous parameter.
Press button 1 to escape.
The relative indicator light on the control board will switch on when the weekly programmer
is active (see display table description).
TO DEACTIVATE THE WEEKLY PROGRAMMER
enter user programming by pressing key 3 and holding,
press key 5, a fl ashing “
0
” will appear on display D2. Set “
OFF
” in display D1 using keys 2 and 3. Then press
key 1 to confi rm and escape.
The manual controls, from the display or remote control, always remain priority with respect to
programming.
PELLET FEED ADJUSTMENT
If the stove has functioning problems owing to the quantity of pellets, adjust pellet feeding directly from
the control board.
The problems correlated to the amount of fuel can be divided into 2 categories:
LACK OF FUEL:
the stove can never develop a suitable fl ame, tending to remain very low even at high powers.
at minimum power the stove tends to almost switch off taking the stove into alarm conditions “
NO
PELL
”.
when the stove displays the “
NO PELL
” alarm, there may be non-burned pellets inside the brazier.
EXCESS FUEL:
the stove develops a very high fl ame even at low power.
the panoramic glass is very dirty, obscuring it almost totally.
the brazier tends to become encrusted, blocking the holes for air intake due to the excessive pellet
feed, as it is only burned partially.
If the problem occurs after only a few months working, check that routine cleaning stated
in the stove booklet, has been carried out correctly.
The regulation to be performed is a percentage. Therefore a modifi cation of this parameter will lead to a
proportional variation of all stove feeding speeds.
To access the percentage adjustment of pellet feeding, enter the user programming by pressing key 3 and,
holding this down, press key 5.
At this point use key 5 to move within the menu until a fl ashing “
F
” appears on display D2.
If, inadvertently, progress is made beyond this parameter, exit using key 1 and repeat the operation.
The value “
00
”will appear on display D1: keys 2 and 3 can be used to adjust the percentage increase/
decrease desired by 5 points per time (the parameter can be varied with a maximum travel from –50 to
+50).