USER PARAMETERS
31
Chapter 8
To confi rm and continue programming, press button 5.
Press button 4 to go back to the previous parameter.
Parameter 4 (D2=4(fl ashing); D1= “00”)
This parameter is reserved for the after-sales service and must not be modifi ed.
Parameter 5 (D2=5(fl ashing); D1=Ex. “15:00”)
Use buttons 2 or 3 to set “
15:00
”, which corresponds to the switch-on time of the 2nd time span. To confi rm
and continue programming, press button 5.
Press button 4 to go back to the previous parameter.
Parameter 6 (D2=6(fl ashing); D1=Ex. “22:00”)
Use buttons 2 or 3 to set “
22:00
”, which corresponds to the switch-off time of the 2nd time span. To confi rm
and continue programming, press button 5.
Press button 4 to go back to the previous parameter.
Parameter 7 (D2=7(fl ashing); D1=Ex. “OFF 1”)
Activate the second time span only Saturday and Sunday. To do this use keys 2 and 3 in the following
way:
a. key 3 - scroll the various days
b. key 2 - enable/disable (ON/OFF) the 1st time span for that day
Example:
Day
Initial value
Function key 2
Final value
Function key 3
MONDAY
OFF1
OFF1
to
ON1
and vice-versa
OFF1
(time deactivated)
Go to next day
TUESDAY
OFF2
OFF2
to
ON2
and vice-versa
OFF2
(time deactivated)
Go to next day
WEDNESDAY
OFF3
OFF3
to
ON3
and vice-versa
OFF3
(time deactivated)
Go to next day
THURSDAY
OFF4
OFF4
to
ON4
and vice-versa
OFF4
(time deactivated)
Go to next day
FRIDAY
OFF5
OFF5
to
ON5
and vice-versa
OFF5
(time deactivated)
Go to next day
SATURDAY
OFF6
OFF6
to
ON6
and vice-versa
ON6
(time span active)
Go to next day
SUNDAY
OFF7
OFF7
to
ON7
and vice-versa
ON7
(time span active)
Go to next day
To confi rm and continue programming, press button 5.
Press button 4 to go back to the previous parameter.
Parameter 8 (D2=8(fl ashing); D1=Ex. “OFF”)
Set at “
OFF
” using buttons 2 or 3, which is found before the time “
00:00
”, in a way to disable the switch-on
of the 3rd time period.
To confi rm and continue programming, press button 5.
Press button 4 to go back to the previous parameter.
Parameter 9 (D2=9(fl ashing); D1=Ex. “OFF”)
Set at “
OFF
” using buttons 2 or 3, which is found before the time “
00:00
”, in a way to disable the switch-off
of the 3rd time period.
To confi rm and continue programming, press button 5.
Press button 4 to go back to the previous parameter.
Summary of Contents for LUCREZIA IDRO LCD
Page 2: ...2 ...
Page 4: ...4 ...
Page 44: ...etichetta codice a barre QUALITY CONTROL 44 QUALITY CONTROL ...
Page 45: ...45 Notes ...
Page 46: ...46 Notes ...
Page 47: ...47 Notes ...