PRODUCT FUNCTIONALITY
24
Chapter 5
State of clamps
State of outputs State of stove
ING1 external contact connected
ING2 external contact connected
ING1 closed and ING2 closed
Stove on
OUT4 deactivated (0 V)
OUT3 active (230 V, 50 Hz )
ING1 open and ING2 closed
Stove on
OUT4 active (230 V, 50 Hz )
OUT3 deactivated (0 V)
ING1 closed and ING2 open
Stove off
OUT4 deactivated (0 V)
OUT3 active (230 V, 50 Hz )
ING1 open and ING2 open
Stove on
OUT4 active (230 V, 50 Hz )
OUT3 deactivated (0 V)
Electrical features applicable external devices:
Max. voltage: 230 V
Frequency: 50 Hz
Max. power per channel: 250 W
EXTERNAL THERMOSTAT FUNCTIONING IN STBY/TOFF MODE (TO ALSO BE USED
FOR TELEPHONIC ACTUATOR)
The Stdby function is also used to further reduce fuel consumption by switching the stove off when the
desired temperature is reached.
Connect one external thermostat in contacts 1 and 2 of the board
1.
When the mechanical thermostat reaches the desired temperature, the stove enters the “
2.
STBY-TOFF
”
phase, automatically switching itself off (external contact closed) and without any delay.
When the external contact opens again, the stove will automatically switch on again.
3.
If this is the function to be used, it is necessary to leave the jumpers connected to the rear
part of the stove, in inputs ING1 and ING2.