PRODUCT FUNCTIONALITY
22
Chapter 5
Commands procedure
Remove and restore the stove power supply using the master switch or using the power supply
1.
cable.
The stove sequentially displays the following items before reaching “
2.
OFF
”:
Microprocessor version (
EXTRAH2O_2
or successive versions)
Mode Selection (
WINTER
as set in the factory)
Language (
LANGUAGE
)
Current day and time adjustment (
CLOCK
)
Level (
LEVEL
setting reserved for authorised technicians)
When “
3.
WINTER
” appears, press button 5 to access the adjustment mode.
Display
4.
D1 will show the mode currently selected while display
D2
will show “
MOD-
”: use keys 2 and 3 to
select the mode from those available:
WINTER/SUMMER/WINTER-DOMESTIC
Once the desired mode has been selected, press button 1 to escape and confi rm.
5.
WINTER MODE
The stove works controlling both thermostats: only when both thermostats are satisfi ed, the stove switches
off after a 15 minutes delay.
State of inputs
ING1
and
ING2
:
Closed contact
D
to be satisfi ed
Open contact
D
satisfi ed (fl ashes
t1
and
t2
on display D2)
The outputs status indicated in the table below are only to be considered valid with the stove water
temperature higher than the anti-condensate threshold.
Winter Mode
State of clamps
State of outputs
State of stove
ING1
external contact connected
ING2
external contact connected
ING1
closed and
ING2
closed
Stove on
OUT4
active (230 V, 50 Hz)
OUT3
deactivated (0 V)
ING1
open and
ING2
closed
Stove on
OUT4
deactivated (0 V)
OUT3
active (230 V, 50 Hz)
ING1
closed and
ING2
open
Stove on
OUT4
active (230 V, 50 Hz)
OUT3
deactivated(0 V)
ING1
open and
ING2
open
Stove off
OUT4
deactivated (0 V)
OUT3
active (230 V, 50 Hz)
SUMMER MODE