SAFETY DEVICES
10
Chapter 3
INSTALLATION AND SAFETY DEVICES
The installation, relative plant connections, commissioning and inspection of correct functioning must
be carried out perfectly, in total compliance with Standards in force, both national and regional, as well as
these instructions.
For Italy, installation must be carried out by profesionally authorised staff (law dated 5 March 1990 n°46).
Extrafl ame S.p.A. declines all liability for damage/injury to objects/persons caused by the plant.
Safety devices for open vessel plant.
According to the UNI 10412-2 (2006) Standard in force in Italy, the plants with open expansion vessel must
have:
Open expansion vessel
Safety pipe
Feed pipe
Pump control thermostat (excluded for natural circulation plants)
Circulation system (excluded for natural circulation plants)
Acoustic alarm activation device
Acoustic alarm
Temperature indicator
Pressure indicator
Automatic circuit breaker switch (block thermostat)
The temperature safety sensors must be in place on the machine at a distance no greater than 30 cm from
the fl ow connection.
Whenever the generators lack a device, those missing can be installed on the thermo product fl ow pipe,
within a distance no greater than 1m from the machine.
SAFETY DEVICES FOR OPEN VESSEL PLANT
According to the UNI 10412-2 (2006) Standard in force in Italy, the plants with open expansion vessel must
have:
Open expansion vessel
Safety pipe
Feed pipe
Pump control thermostat (excluded for natural circulation plants)
Circulation system (excluded for natural circulation plants)
Acoustic alarm activation device
Acoustic alarm
Temperature indicator
Pressure indicator
Automatic circuit breaker switch (block thermostat)
The temperature safety sensors must be in place on the machine at a distance no greater than 30 cm from
the fl ow connection.
Whenever the generators lack a device, those missing can be installed on the thermo product fl ow pipe,
within a distance no greater than 1m from the machine.