51
HPS-III-Heißkanalsystem_Elektro-System_BA_V-2-0_EN
5.6.7 Wiring of 8-drop hot runner systems (manifold with 2 control zones)
z218-06
Picture 38: Wiring of standard-8-drop hot runner systems (manifold with two control zones)
Key to the symbols
Z
Control zone
H
Heater nozzle
M
Heater manifold
CN
Heater band
sprue bush
T
Thermocouple
PE
Protective earth
conductor
L
Phase conductor
N
Neutral conductor
male
female
X-1.2
+
8
7
6
5
4
3
2
1
-
16
15
14
13
12
11
10
9
+
24
23
22
21
20
19
18
17
-
32
31
30
29
28
27
26
25
N
20
19
18
17
16
15
14
13
L
8
7
6
5
4
3
2
1
21
9
22
10
23
11
24
12
X-1.1
230 V
Thermo
Control
zone
Z
Plug 230 V / 24-pin
No. = X...
Contact
L / N
Plug thermo / 32-pin
No. = X...
Contact
+ / -
Z-01
X-1.1
H-01
1 / 13
X-1.2
T-01
1 / 9
Z-02
X-1.1
H-02
2 / 14
X-1.2
T-02
2 / 10
Z-03
X-1.1
H-03
3 / 15
X-1.2
T-03
3 / 11
Z-04
X-1.1
H-04
4 / 16
X-1.2
T-04
4 / 12
Z-05
X-1.1
H-05
5 / 17
X-1.2
T-05
5 / 13
Z-06
X-1.1
H-06
6 / 18
X-1.2
T-06
6 / 14
Z-07
X-1.1
H-07
7 / 19
X-1.2
T-07
7 / 15
Z-08
X-1.1
H-08
8 / 20
X-1.2
T-08
8 / 16
Z-09
X-1.1
M-01
9 / 21
X-1.2
T-09
17 / 25
Z-10
X-1.1
M-02
10 / 22
X-1.2
T-10
18 / 26
Z-11
X-1.1
CN-01
11 / 23
X-1.2
T-11
19 / 27
Electrical connection of hot runner systems