16
HPS-III-Heißkanalsystem_Vorspann_BA_V-2-0_EN
Technical data
3. Technical data
3.1
Mechanical specifications
3.1.1 Main dimensions of the HPS III hot runner system
Description
Quantity/size (approx.)
Unit
Dimensions
See catalogue / PO-related documents mm
Weight
See catalogue / PO-related documents kg
Chart 2: Main dimensions of the HPS III hot runner system
3.1.2 Operating parameters of the HPS III hot runner system
Description
Quantity/size (approx.)
Unit
Maximum injection pressure
2000 bar
Maximum operating temperature
Depending on order °C
Chart 3: Operating parameters of the HPS III hot runner system
3.2
Electrical specifications
3.2.1 Connections/connector pin assignment
Description
Quantity/size (approx.)
Unit
Voltage
230 V
Frequency
50 Hz
Chart 4: Electrical data (only valid within the EU)
3.3
Hydraulic / pneumatic specifications (drive units)
Description
Quantity/size (approx.)
Unit
Maximum hydraulic pressure (normal operation: 30 bar)
50 bar
Maximum pneumatic pressure (normal operation: 8 bar)
10 bar
Chart 5: Hydraulic / pneumatic data
3.4 Operating conditions
Operating conditions
Size (approx.)
Unit
Ambient temperature (maximum value)
40 °C
Ambient temperature (minimum value)
10 °C
Relative humidity during operation (no condensation!)
20 to 80 %
Chart 6: Operating conditions
3.4.1 Noise emission
Determining the sound power level of noise sources based on noise pressure measurements acc. to DIN EN ISO 3741
Operating conditions
Size (approx.)
Unit
Distance to device
* mm
Noise pressure level (operation)
* dB (A)
Chart 7: Noise emission
* Values can be determined only after the entire system has been started up.