![EWIKON HPS III Operating Manual Download Page 139](http://html1.mh-extra.com/html/ewikon/hps-iii/hps-iii_operating-manual_2448015139.webp)
139
HPS-III-Heißkanalsystem_Anziehdrehmomente-Düsenspitzen_BA_V-2-0_EN
9.3 Tightening torques for tip inserts
Flow channel Ø
of nozzle
3 mm
4.5 mm
6 mm
9 mm
12 mm
18 mm
Thread G
M5x0.5
M7x0.5
M10x0.75
M13x0.75
M16x0.75
M24x1.0
Nosepiece
SW8
SW8
SW9
SW12
SW16
SW24
Screw-on gate
bush
SW8
SW11
SW13
SW17
SW24
SW27
HPSIII-S
95158...
95159...
95218...
95219..
95258-V01...
95259-V01...
95308-V01...
95309-V01...
95408-V01...
95409-V01...
95538...
HPSIII-SXE
-
-
93259...
93309...
93409...
93539...
HPSIII-NVE
NV95158...
NV95159...
NV95218...
NV95219...
NV95258-V01...
NV95259-V01...
NV95308-V01...
NV95309-V01...
NV95408-V01...
NV95309-V01...
NV95538...
HPSIII-NVI
-
-
EN306...L
EN309...L
EN312...L
EN312...H
EN218...L
EN218...H
HPSIII-L2X
-
-
95063....
95093....
95123....
95182....
HPSIII-L2X-NV
-
-
NV95063...
NV95093...
NV95123...
NV95182..
HPSIII-MV
95...-3 / 95...-4
93...-3
-
-
-
-
-
Tightening
torque [Nm]
3.5
3.5
13
30
50
100
Tightening
torque [ft·lb]
2.6
2.6
9.6
22.1
36.9
73.8
Chart 15: Tightening torques for tip inserts
z253-06
Picture 112: Examples of tip inserts
1
Tip insert
2
Tip insert including nosepiece (one-piece)
3 Nosepiece
4
Screw-on gate bush
5
Extended screw-on gate bush
G Thread
SW
Width across flats
Please pay attention to the notes in chapter „5. Installation“ and
chapter „7. Maintenance“.
The threads (G) of the tip inserts must be coated with high tempe-
rature installation paste (see chapter „5.3.1 Tools and operating ma-
terials“.
Installation temperature 220°C.
Non-standard tip inserts may require tightening torques which dif-
fer from the values given here. In case of doubt always contact
EWIKON.
NOTE!
Tightening torques
Summary of Contents for HPS III