20
04-2017 5325 00
ELECTRICAL CONNECTION
The appliance is designed to work with a
single-phase voltage of 120 V∿;
the appli-
ance must be connected to an electric
mains with a maximum impedance (Z)
of 0.3898 ohm.
For the connection, make sure that the
nameplate details correspond to those of
the mains, and in particular that: the voltage
is within the recommended limits for the
connection points;
It is mandatory to use a main switch,
in accordance with the current instal-
lation standards and make sure that
it is located in an accessible position.
The switch must have the suitable char-
acteristics to withstand the maximum
required load and ensure a complete
disconnection from the power sup-
ply under conditions of overvoltage
category III and, therefore, protect the
circuit against ground faults, overloads
and short circuits.
The switch, the socket and the plug must
be placed in an accessible position.
The electrical safety of the appliance is
ensured only when the machine is correctly
connected to an efficient earthling system,
as foreseen by the current safety regula-
tions.
It is important to have this fundamental
requirement checked. If in doubt, have
the system carefully checked by a qual
-
ified professional.
The power supply cable has a non-sep-
arable plug; The replacement of the con-
nection cable shall be carried out only by
qualified personnel and using only flex
-
ible cables of the type SJTW 14AWG /3C
105 °C BLACK with NEMA 5-15P certified
plug with GFCI (ground fault circuit inter-
rupter) of the same characteristics.
The use of adapters, multiple plugs
and/or extension leads is forbidden.
The manufacturer shall not be held re-
sponsible for any damage caused due
to the non-observance of the above-
mentioned precautions.
1
3
1
2
Fig. 16
1. Lid that opens
2. Cable clamp terminal
3. Power cable