Manual instruction MM850482 ed.04
23
•
Press the [
ENTER
] key: the depression value will be displayed on the following page
NOTE:
TO STORE THE DRAFT VALUE AND PRINT IT ON THE FLUE GAS ANALYSIS REPORT
,
PRESS THE
[DRAFT]
KEY
.
T
HE
SYMBOL
"M"
WILL BE DISPLAYED INSTEAD OF THE
"E"
Press
[
DRAFT
] again if you want remove the HOLD function (the draft value will not be printed on the gas
analysis report)
Press
[
ESC
] to return to the measuring page.
6.1.6 Temperature
Measurement
The flue gas analyser is equipped with two temperature inputs for Pt100 and TC Type K probes. The
temperature probes are useful to measuring air, water and contact temperature. Connect the Pt100 probe to
the "Tair" input as shown in figure 1.
Connect the TC Type K probe to the mini-DIN compensated "Tgas" input as shown in figure 2. The instrument
features the compensation of the cold joint: it means that of a Pt100 thermoresistance detect the temperature
in correspondence of thermocouple connector.
FIG.1
FIG. 2