![Eurotech PCN-1001 User Manual Download Page 113](http://html1.mh-extra.com/html/eurotech/pcn-1001/pcn-1001_user-manual_2440322113.webp)
Standards
Compliance
PCN-1001 User manual
Standards Compliance
TEST
STANDARD FOLLOWED
RESTRICTION
TYPE
ROUTINE
Visual inspection
EN 50155 Section 10.2.1
*
*
Performance test
EN 50155 Section 10.2.2
Low limit: 9V
High limit: 32V
Interruption: Class 1 (no interruptions)
*
*
Cooling test
EN 50155 Section 10.2.3
Class T1: -20°C (§ 10.2.3)
*
-
Dry heat test
EN 50155 Section 10.2.4
Class T1: +55°C (§ 10.2.4)
*
-
Power supply over-voltages
EN 50155 Section 10.2.6.1
40V for 100ms (1ohm)
*
-
Surges
EN 50155 Section 10.2.6.2
(EN 50121-3-2)
On Battery:
•
Waveform A
•
1,8 kV 5/10 us, Rs=100Ω
•
Performance criteria B
*
-
Transient burst susceptibility
test
EN 50155 Section 10.2.7
(EN 50121-3-2 / EN 61000-4-4)
On I/O ports and Battery:
•
+/- 2 kV (peak)
•
5/50 Tr/Th ns
•
5 kHz Rep. Frequency
*
-
Conducted radio frequency
susceptibility test
EN 50155 Section 10.2.8.1
(EN 50121-3-2 / EN 61000-4-6)
On I/O ports and Battery:
•
10 Veff (carrier voltage)
•
0,15 – 80 MHz, 1 KHz, 80 % AM
•
Source impedance: 150 Ω
•
Performance criteria: A
*
-
Radio frequency susceptibility
test
EN 50155 Section 10.2.8.1
(EN 50121-3-2/ EN 61000-4-3)
On the enclosure port:
•
20 V/m
•
80 MHz 1 GHz, 1 KHz, 80 % AM
•
Source impedance: 150 Ω
•
Performance criteria: A
*
-
Radio frequency susceptibility
test with pulse modulation
ENV50204
On the enclosure port:
•
10 V/m
•
900 MHz +-5 MHz
•
1,89 GHz +-10 MHz
•
Performance criteria: A
*
-
Electrostatic discharge
EN 61000-4-2 /A1 /A2
On the enclosure port:
•
6KV contact discharge
•
8KV air discharge
•
Performance criteria: B
*
-
Conducted emission
EN 55022 / A1
EN 50155 Section 10.2.8.2
(EN 50121-3-2 / 55011 )
On Battery:
•
0,15 – 0,5 MHz: 66-
56 dB μV
•
0,5 –
5 MHz: 56 dB μV
•
5 –
30 MHz: 60 dB μV
•
quasi-peak measured at 3m
*
-
Radiated emission
EN 55022 / A1
EN 50155 Section 10.2.8.2
(EN 50121-3-2 / 55011)
On the enclosure port:
•
30 –
230 MHz: 40 dB μV/m
•
230 MHz – 1 GHz: 47 d
B μ V/m
•
quasi-peak measured at 3m
*
-
Insulation resistance
EN 50155 Section 10.2.9
500Vac@1min
*
-
Electrical transient conduction
along supply lines.
ISO-7637-2
Pulses: 1, 2a 2b, 3a 3b, 4
Test level: III
Functional status: Class D
*
-
Radiated emission
ECE ONU Regulation 10
*
-
Random vibrations
EN 50155 Section 10.2.11
EN61373 (ed. 2000) Section 8
Category 1 Class B
*
-
Simulated long life testing
EN 50155 Section 10.2.11
EN61373 (ed. 2000) Section 9
Category 1 Class B
*
-
Shocks
EN 50155 Section 10.2.11
EN61373 (ed. 2000) Section 10
Category 1 Class B
*
-
Safety
EN 60950
Essential constraints defined in the
standard
*
-
* Performed
- Not performed
Summary of Contents for PCN-1001
Page 1: ...PCN 1001 Passenger People Counter USER MANUAL Rev 4 0 23 December 2011 PCN 1001_UserMan_En_4 0...
Page 13: ...Part 1 Introduction PCN 1001 User manual 13 PCN 1001_UserMan_En_4 0 PART 1 INTRODUCTION...
Page 14: ...This page has been intentionally left blank...
Page 22: ...This page has been intentionally left blank...
Page 32: ...This page has been intentionally left blank...
Page 48: ...This page has been intentionally left blank...
Page 50: ...This page has been intentionally left blank...
Page 97: ...APPENDIX PCN 1001 User manual 97 PCN 1001_UserMan_En_4 0 APPENDIX...
Page 98: ...This page has been intentionally left blank...
Page 110: ...This page has been intentionally left blank...
Page 114: ...This page has been intentionally left blank...
Page 116: ...This page has been intentionally left blank...
Page 117: ...Notes PCN 1001 User manual 117 PCN 1001_UserMan_En_4 0 Notes...