The following table lists the options available for the
Serial Ports Table
. At least one row of the
Serial
Ports Table
is required for the Terminal Server to operate.
FIELD/OPTION
EXPLANATION
COM Port
Select the serial COM port to which the Terminal Server data is sent.
Important:
Make sure this COM port is not configured for another service in
the ZyWAN-G9. Otherwise, both services may conflict for the port
and not operate correctly.
It is possible in some applications to configure two Terminal
Servers to use the same COM port. In order for this to work, the
Demark
option must be set to
Half Duplex
or
Broadcast
. In
Half
Duplex
mode, the clients connecting to each port may need to wait
much longer for a response, since the
Demark
and
Response
Timeout
times for all connections are observed, in the order that
the requests are received from each client.
Baud Rate
Select the baud rate to use for the Terminal Server port. Baud rate options range
from 1200 to 115,200 bps.
Data Bits
Select the number of data bits to use for the Terminal Server port. Options are
5
,
6
,
7
, and
8
.
Parity
Select the parity to use for the Terminal Server port. Options are
None
,
Odd
,
Even
,
Mark
,
Space
.
Stop Bits
Select the number of stop bits to use for the Terminal Server port. Options are
1
,
1.5
,
and
2
.
Flow Control
Select whether to use hardware flow control for the Terminal Server port. Options are
None
, and
RTS/CTS
(hardware flow control).
Summary of Contents for 930150-4003R
Page 13: ...Introduction 13 110150 4002A This page intentionally blank ...
Page 14: ......
Page 15: ...PART 1 GETTING STARTED 15 110150 4002A PART 1 GETTING STARTED ...
Page 40: ...ZyWAN G9 User Manual 40 110150 4002A This page intentionally blank ...
Page 41: ...PART 2 SOFTWARE CONFIGURATION 41 110150 4002A PART 2 SOFTWARE CONFIGURATION ...
Page 106: ...PART 3 CONFIGURATION EXAMPLES 106 110150 4002A PART 3 CONFIGURATION EXAMPLES ...