ZyWAN-G9 - User Manual
80
110150-4002A
translates from the source (internal) network. Each of the four fields must
be a number between 0 and 255. For instance, entering an IP address
network of 172.16.11.0 translates all addresses from 172.16.11.1 through
172.16.11.255.
Source Netmask
Enter the subnet mask for the
Source Network/Address
. Each of the four
fields must be a number between 0 and 255.
Source Interface
Enter the name of the network interface which contains the source network
(above).
Destination Interface
Enter the name of the network interface which is the destination (external)
side of the network address translation. The public IP address on that
interface has already been defined in the
Ethernet
or
WiFi
sections of the
configuration, or it might be assigned by the cellular provider as part of the
data services activation on that network. The interface names must be
entered such as
eth0
or
ppp0
Understanding Network Interfaces
for a description of the available interfaces on the ZyWAN-G9.
Masquerade
The normal setting for
Masquerade
is Yes, providing forwarding and
Network Address Translation between the two interfaces.
There may be rare cases where this should be set to
No
, which retains the
internal forwarding of packets between the two interfaces, but disables the
network address translation.
Time Synchronization
Select the method of synchronizing the internal clock of the ZyWAN-G9. Available options are:
None
,
GPS
, and
NTP
. The GPS option allows the time to be acquired from the GPS receiver (if installed).
The NTP (Network Time Protocol) updates the clock using NTP protocol from a network server. The
following screen capture shows the
Table of NTP Servers
table available if
Time Synchronization
is set
to
NTP
.
The following table lists the buttons available.
BUTTON
EXPLANATION
Insert Row#
Each of the table rows is numbered. In order to insert a row in the table,
enter a number in the box between 1 and one greater than the highest
number of rows. Then click the
Insert Row#
button to insert a blank row.
This row needs to be filled in with all data required.
Delete Row#
In order to delete a row in the table, enter a number in the box between 1
and the highest number of rows. Then click the
Delete Row#
button to
delete the row. Once a row is deleted, it cannot be restored without inserting
a row and entering the data again.
Note:
If the clock is not retained after loss of power, it may
either be that the battery link on the main circuit board is
not fitted or that the coin cell battery has failed and
needs to be replaced.
Summary of Contents for 930150-4003R
Page 13: ...Introduction 13 110150 4002A This page intentionally blank ...
Page 14: ......
Page 15: ...PART 1 GETTING STARTED 15 110150 4002A PART 1 GETTING STARTED ...
Page 40: ...ZyWAN G9 User Manual 40 110150 4002A This page intentionally blank ...
Page 41: ...PART 2 SOFTWARE CONFIGURATION 41 110150 4002A PART 2 SOFTWARE CONFIGURATION ...
Page 106: ...PART 3 CONFIGURATION EXAMPLES 106 110150 4002A PART 3 CONFIGURATION EXAMPLES ...