ZyWAN-G9 - User Manual
92
110150-4002A
The following table lists the fields and options available for each row of the
Host Connection Table
.
Multiple rows may be added if necessary:
FIELD/OPTION
EXPLANATION
Remote IP Port
Enter the port number (between 1 and 65535) to which the Terminal Client
connects. The same port number is used to attempt connections to each of
the three IP Addresses, if configured. There is no option to connect to
different port numbers for each address in the Host Connection row.
Disconnect Mode
Select when to disconnect from the remote address. In any case of a
session disconnect, the
Connect Mode
(above) determines how a
reconnection occurs.
Options available are:
On +++
: Disconnect if three char++ (and no more than three) are
received on the serial port within the
Demark Time
. This emulates the
modem attention string often used prior to hanging up a dial connection.
On Dropped DCD
: Disconnect when the Data Carrier Detect (DCD) input on
the serial port goes to a low (inactive) state.
Either
: Disconnect either on rec++ at the serial port or on an inactive
serial DCD line.
Neither
: Never disconnect from the remote server. Connections may still be
lost due to the remote side dropping its connection or due to network
interruptions.
Echo Connect Strings?
Choose whether to echo all commands.
The options are:
To Async
: Echo the Connect Message and Failure Message to the serial
port after a connection attempt or after the Terminal Client disconnects.
To Async and Socket
: Echo the
Connect Message
and
Failure Message
to
the serial port and to the remote server after a connection attempt or after
the Terminal Client disconnects.
Neither
: Do not echo the strings to the serial or TCP port.
Matching Dial String
Enter the ATDT string that is used to make a connection if the
Connect
Mode
option is set to
ATDT
or
ATDT
or
DCD
. Otherwise, this field must be
left empty.
If used, the string must always start with the letters
ATDT
and be followed
by some unique text (uppercase/lowercase text is treated identically, and
spaces are ignored).
For instance, the Host Connection rows may contain
Matching Dial Strings
of ATDT1, ATDT555-1212, ATDTDIAL. When any of these strings is
received on the serial port, the ZyWAN-G9 attempts to connect to the first
configured IP address of its Host Connection row.
Connect Message
Enter a
text message (such as “CONNECT”) sent to the network and/or
serial port when a network connection is established to the remote address.
This text is only sent when the
Echo Connect Strings?
is set to something
other than
Neither
. This option emulates a
modem‟s option to echo a
connect message to a dialing computer. This field may be left blank if no
message is desired.
Failure Message
Enter a text message (such as “NO CARRIER”) sent to the network and/or
serial port when the Terminal Client disconnects from a network connection
and to the serial port when a connection attempt fails. This text is only sent
when the
Echo Connect Strings?
is set to something other than
Neither
.
This option emulates a modem‟s option to echo a fail message to a dialing
computer. This field may be left blank if no message is desired.
IP Address 1,
IP Address 2,
IP Address 3
Enter the IP address or fully qualified domain name (URL or FQDN) to
which the Terminal Client connects.
Summary of Contents for 930150-4003R
Page 13: ...Introduction 13 110150 4002A This page intentionally blank ...
Page 14: ......
Page 15: ...PART 1 GETTING STARTED 15 110150 4002A PART 1 GETTING STARTED ...
Page 40: ...ZyWAN G9 User Manual 40 110150 4002A This page intentionally blank ...
Page 41: ...PART 2 SOFTWARE CONFIGURATION 41 110150 4002A PART 2 SOFTWARE CONFIGURATION ...
Page 106: ...PART 3 CONFIGURATION EXAMPLES 106 110150 4002A PART 3 CONFIGURATION EXAMPLES ...