37
Control command switch terminal 2
Used to switch between terminal control and communication control. If the command source is
selected as terminal control, the system will be switched to the communication control mode when
the terminal is active; vice versa.
38
PID integral pause
When the terminal is active, the PID integral adjustment function is paused, but the proportion and
differential adjustments of PID are still valid.
39
Switch between frequency source
master setting and preset frequency
When the terminal is active, the frequency source A is replaced by the preset frequency (F0.01)
40
Switch between frequency source
auxiliary setting and preset frequency
When the terminal is active, the frequency source B is replaced with the preset frequency (F0.01)
43
PID parameter switching
When DI terminal (E2.19 = 1) is used to switch PID parameters, if the terminal is invalid, PID
parameters use E2.13~E2.15; if the terminal is valid, PID parameters use E2.16~E2.18
44
Custom fault 1
When custom fault 1 and custom fault 2 are active, the inverter respectively alarms fault Err.27 and
fault Err.28, and deals with them according to the mode selected by the fault protection action
F8.19.
45
Custom fault 2
47
Emergency parking
If the terminal is valid, the inverter will park at the fastest speed, and the current maintains at the
set upper limit during the parking process. This function is used to meet the requirements that the
inverter needs to stop as soon as possible when the system is in a emergency state.
48
External parking terminal 2
In any control mode (Keyboard control, terminal control, communication control), the terminal
can be used to decelerate the inverter until stop, at the time the deceleration time is fixed for
deceleration time 4.
49
Deceleration DC braking
If the terminal is valid, firstly the inverter decelerates to the initial frequency of stop DC braking, and
then switches directly to DC braking status.
50
Clear current running time
If the terminal is valid, the inverter’s current running time is cleared
Table 1 Multi command functions description:Over 4 segments command terminal, can be combined into 16 states,
each state corresponds to the 16 instruction set value. As shown in Table 1 below:
K4
K3
K2
K1
Command Setting
Parameters
OFF
OFF
OFF
OFF
0-Stage speed setting 0X
E1.00
OFF
OFF
OFF
ON
1-Stage speed setting 1X
E1.01
OFF
OFF
ON
OFF
2-Stage speed setting 2X
E1.02
OFF
OFF
ON
ON
3-Stage speed setting 3X
E1.03
OFF
ON
OFF
OFF
4-Stage speed setting 4X
E1.04
OFF
ON
OFF
ON
5-Stage speed setting 5X
E1.05
OFF
ON
ON
OFF
6-Stage speed setting 6X
E1.06
OFF
ON
ON
ON
7-Stage speed setting 7X
E1.07
ON
OFF
OFF
OFF
8-Stage speed setting 8X
E1.08
ON
OFF
OFF
ON
9-Stage speed setting 9X
E1.09
ON
OFF
ON
OFF
10-Stage speed setting 10X
E1.10
ON
OFF
ON
ON
11-Stage speed setting 11X
E1.11
ON
ON
OFF
OFF
12-Stage speed setting 12X
E1.12
ON
ON
OFF
ON
13-Stage speed setting 13X
E1.13
ON
ON
ON
OFF
14-Stage speed setting 14X
E1.14
ON
ON
ON
ON
15 Stage speed setting 15X
E1.15
Code
Parameter name
Setting range
Factory setting Change
F1.10
Terminal command mode
0: Two-wire type 1 1;
1: Two-wire type 2 2;
2: Three-wire type 1;
3: Three-wire type 2
0
★
F1.11
TerminalUP/DOWN
0.001Hz/s~65.535Hz/s
1.000Hz/s
☆
F1.12
Minimum input for AIC1
0.00V~F1.14
0.30V
☆
F1.13
F1.12 corresponding setting
-100.0%~+100.0%
0.0%
☆
F1.14
Maximum input for AIC1
F1.12~+10.00V
10.00V
☆
F1.15
F1.14 corresponding setting
-100.0%~+100.0%
100.0%
☆
F1.25
AIinput setting selection
Units digit:AI1 AI1 Below the minimum input setting selection
0: Corresponding to the minimum input set 1:0.0%;
000
☆
F1.30
DI filter time
0.000s~1.000s
0.010s
☆
F1.31
AI1 filter time
0.00s~10.00s
0.10s
☆
F1.35
DI terminal Mode slection 1
Units digit:DI1 :
0: High level active; 1: Low level active
Tens digit: DI2 (Same as the units digit);
Hundreds digit: DI3 (Same as the units digit)
Thousands digit: DI4 (Same as the units digit));
Ten thousands digit: DI5 (Same as the units digit)
00000
★
F1.37
DI1 delay time
0.0s~3600.0s
0.0s
★
F1.38
DI2 delay time
0.0s~3600.0s
0.0s
★
F1.39
DI3 delay time
0.0s~3600.0s
0.0s
★
F1.40
Define the input terminal repeat
0: Unrepeatable;
1: Repeatable
0
★