Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL •
T
+31(0)252 228850 •
F
+31(0)252 228235 •
E
I
euronormdrives.com
Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL •
T
+31(0)252 228850 •
F
+31(0)252 228235 •
E
I
euronormdrives.com
8
9
EURN010000_
002_C
EURN010000_
002_C
7. Parameter list
In JI150 series frequency inverters ,some parameters are “manufacturer reserved”, and their serial numbers are not listed
in the function parameter table,which leads to the discontinuity of some parameter serial numbers in the table. For the
parameters not introduced in the manual, please do not attempt to modify them to avoid causing errors.
d0 group Monitoring function group
Code
Parameter name
Functional Description
Factory setting
d0.00
Running frequency
Inverter theoretical operating frequency
0.01Hz
d0.01
Set frequency
Actual set frequency
0.01Hz
d0.02
DC bus voltage
Detected value for DC bus voltage
0.1V
d0.03
Output voltage
Actual output voltage
1V
d0.04
Output current
Effective value for Actual motor current
0.01A
d0.05
Output power
Calculated value for motor output power
0.1kW
d0.06
Output torque
Motor output torque percentage
0.1%
d0.07
DI input status
DI input status
-
d0.08
DO output status
DO output status
-
d0.09
AI1 voltage
AI1 input voltage value
0.01V
d0.12
Count value
Actual pulse count value in counting function
-
d0.13
Length value
Actual length in fixed length function -
-
d0.14
Actual operating speed
Motor actual running speed
-
d0.15
PID setting
Reference value percentage when PID runs
%
d0.16
PID feedback
Feedback value percentage when PID runs
%
d0.17
PLC stage
PLC Stage display when PLC runs
-
d0.19
Feedback speed
Inverter actual output frequency
0.01Hz
d0.20
Remaining run time
Remaining run time display, it is for timing run control
0.1Min
d0.22
Current power-on time
Total time of current inverter power-on
1Min
d0.23
Current run time
Total time of current inverter run
0.1Min
d0.25
Communication set value
Frequency, torque or other command values set by communication port
0.01%
d0.27
Master frequency setting display
Frequency set by F0.03 master frequency setting source
0.01Hz
d0.28
Auxiliary frequency setting display
Frequency set by F0.04 auxiliary frequency setting source
0.01Hz
d0.35
Inverter status
Display the running and standby etc status information
-
d0.36
Inverter type
1:G type: Suitable for constant torque load
-
d0.37
AI1 voltage before correction
Input voltage value before linear correction of AI1
0.01V