X410 is listed but part of the output reads Reachable: no, then your firewall
is blocking some communication with the device. If there are no problems
indicated by the output, run uhd_usrp_probe --args addr=<device IP address>
to test connectivity over Ethernet. If the command runs successfully but
LabVIEW still cannot connect, load a different bitfile on the device.
Why Can't I Detect My Device in LabVIEW?
Complete one or more of the following options to detect your device in LabVIEW:
■
Ensure that the device has been updated with an NI-USRP compatible FPGA.
■
Ensure that the device is powered on and has a valid IP address.
■
Refer to the NI-USRP Readme to verify that your version of the NI-USRP
instrument driver supports the Ettus USRP X410.
UHD
Setting Up the Device
Ensure that all of your hardware components are powered off before installing.
1. Verify that you have all items included in your device kit and the following
additional items.
■
Host PC
■
Network switch
■
CAT 5E Ethernet Cable (optional)
■
One of the following:
■
QSFP28 to QSFP28 Ethernet cable and 100 Gb Ethernet network card
■
QSFP28 to 4xSFP28 Ethernet breakout cable and 10 Gb Ethernet network
card
2. Set all items on a flat surface near power outlets and a modem or router.
3. Follow the instructions included with your network switch to connect it to a
modem or router.