p. 110 Esmach S.p.A. Grisignano di Zocco (VI) - I
SPI 30-200 F
Instructions for use
and maintenance
… continue SPI 30 E - SPI 45, versione E
Card displays show “---“ “---
“
▪
Emergency button pressed
Re-establish the emergency button in
turning it in counter-clockwise direction.
While operating the bowl
swings noticeably
▪
Check the play to be 2-3 mm between bowl
and sliding block
Check bowl pusher sliding block and, if
needed, replace it (par.4.4.1).
Card display shows ERR
007
▪
Grid protection safety microswitch
NC and NO entry are both present on
the card. Check the operating of card
and micro.
SPI 60 - 80 - 100 - 130 - 160 - 200, “E” Version
Failure/Anomaly
Possible Cause
Possible Remedy
Main power switch in
position
ON
-
I
, the card
leds do not switch on
▪
Glass fuse ( in the card ) has a fault
▪
Transformer protection fuses burnt
▪
External power switch on: OFF-O
▪
Main power switch has a fault
Check and eventually carry out the
works needed by replacing the defective
parts.
By pressing the button start,
the machine does not start
▪
Emergency button pressed
▪
Start button defective
▪
Bowl cover lifted up
Re-establish the emergency button in
turning it in clockwise direction.
Check and, if needed, replace the
defective parts.
Close the cover bowl
During operating, the
machine stops and the card
display shows ERR 002
▪
Excessive bowl filling up
▪
Magnetothermic switch disconnected
▪
Bowl protection microswitch
▪
the machine has reached the max. time set
for the 1
st
speed ; after 2 seconds the
errors re-establish automatically
Check if the external power switch is on
OFF- O and open the electrical box :
check the magnetotermic switch
Check the efficiency of cover micro.
If no positive result is achieved, contact
the Technical Service.
In
AUTOMATIC
mode the
machine does not switch
from 1
st
to 2
a
speed ( 2
nd
speed time vel.
≠
0)
▪
Card has a fault
Check and eventually contact the
Technical Service .
Card displays show ERR
001
▪
Card keys pressed while switching on
Check the state of keys; if needed
contact the Technical Service.
Replace the card.
Card displays show ERR
003
▪
EEPROM memory malfunctioning
Contact the Technical Service.
Replace the card.
Card displays show ERR
004
▪
Brale has a fault/ brake control circuit
▪
Fuse has a fault
Check the brake funtion .
Check the glass fuse (1.6 A) on the
electronic card.
Check and eventually contact the
Technical Service .
Card displays show ERR
005
▪
Brake power relay has a fault
Check and, if needed, contact the
Technical Service to replace the card.
Card displays show ERR
007
▪
Grid protection safety microswitch
NC and NO entry are both present on
the card. Check the operating of card
and micro.