p. 92 Esmach S.p.A. Grisignano di Zocco (VI) - I
SPI 30-200 F
Instructions for use
and maintenance
3.3.5.2.2.1 HOW TO SET UP THE TEMPERATURE VALUE IN A PROGRAM
For each program ( from 0 to 9) a different temperature value can be set, but in the range between 0 °C and
65 °C (32 °F and 149 °F). To set and store the temp erature value in a program, proceed as follows:
-press repeatedly the button (9) until the program required is shown on the display (8)
-press the key
PROGRAM (9
) for about 3 seconds and keep it pressed until the led (10) switches on and the
display (8) starts blinking.
-press again the key (9) ( the display (19) blinks); set the temperature through the keys (3),(4),(6),(7)
-if the machine has no ingredient dispenser systems, by pressing the key (9) for 3 seconds, it is possible to
go out from
PROGRAMMING
(the led (10) switches off and the display (8)stops blinking), and the data are
saved; otherwise switch to the programming of the 1° dispenser ( par. 3.3.5.3)
If the set up temperature value has been exceeded, this may depend on the following :
a)machine not in operation: the display (19) blinks, showing the value of the temperature every 4 seconds
b)machine in operation: the display (19) blinks, as in case a), and ( only the first time when the temperature
value set exceeds, then no more) the acoustic alarm is activated for a time of 10 seconds.
The warning time is set up through the parameter P05 ( see par. 3.3.5.6)
3.3.5.3
INGREDIENT DISPENSER (D1 – D2 DISPENSER)
The machine is equipped with one or two dispensers; or it may be without any dispenser according to the
contractual agreement.
It is possible to program the delay time for each D1 and/or D2 dispenser, through which the ingredients to
distribute are to be added after the START or the advance time through which the beginning of the ingredient
addition is possible compared to the scheduled end of the cycle. The distribution occurs when the machine
is operating only, independent from the ongoing operation step, but it does not happen if the machine is in
STOP mode.
If the distribution has begun and the STOP button (16) is pressed or the bowl cover is lifted, the ongoing
distribution shall be completed.
The distribution time has to be always lower than the entire time of the cycle, i.e. than the sum of 1
st
e 2
nd
speed mixture time ; in the case a higher time is set up ( and this is wrong!), while programming, the display
(2) shows ERR 009, the display (5) shows “d1” or “d2” depending of the dispenser concerned; it shall be
impossible to go out from
PROGRAMMING.
For each program (from 0 to 9) it is possible to schedule different dispenser times:
-keep the key (9) pressed for about 3 seconds until the led (10) switches on and the display (8) starts
flashing
- press the key (9) until the display (19) shows a flashing “d1”; through the keys (3),84),(6),(7) ( - de
increase ), set up the time needed ( advance or delay depending on how the parameter P09 has been set up).
If the machine is equipped with one D1 dispenser only, by pressing the key (9) for 3 seconds, it is possible to
go out from the
PROGRAMMING
and the data set are saved. Instead, if the machine is equipped with a
second dispenser, it is possible to switch to D2 dispenser programming, and this scheduling will follow the
same operation mode as described per D1 dispenser.
The choice of the “delay” time ( select “r”; see scheme below, Picture A) or “advance” time (select “A”, see
scheme below, Picture B) to begin the ingredient dosage is made in setting the parameter P09 for D1
dispenser and parameter P11 for D2 dispenser; for the two both the pre-set data is “delay”.
16
2
5
9
10
19
3
4
6
7
A
15
8
B